3-4 Command Parameter List
3-33
3
Communicating with the SK-1000 Series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
*3 Use this parameter in combination with the judgment value property or with the
judgment value "invalid," "over," or "under."
If the judgment value is correct, the parameter range is from - 99.997 to 99.998
・ from - 99.999 to 99.999 (SK-050).
• When the current value is over range, "99.999" is stored.
When the current value is under range, "- 99.999" is stored.
When the current value is invalid, "- 99.998" is stored.
When an error occurs, "100.000" is stored.
*4 • When in sample hold:
Value "-99.998" is output.
• When not in sample hold:
The peak value encountered during the sampling period is output
*5 • When in sample hold:
Value "-99.998" is output.
• Wh
en not in sample hold:
The bottom value e
ncountered during the sampling period is output
*6 This is -999.8 when the temperature is not acquired correctly.
*7 This is 999.8 when the humidity is not acquired correctly.
*8 If a prohibited combination of functions is written, it results in "abnormal setting
(1)" For details of each function, refer to the SK-1000 Series Instruction Manual.
*9 The result of the "initial reset request" motion command is included in this item.
Regarding Data No. nn35 (EEPROM writing result), a "0: writing in progress"
status is maintained for 2 seconds after completion of the final write command
transmission to the nonvolatile memory (EEPROM). Writing begins 2 seconds
later, and if completed normally, the result is "1: successfully completed".
[Example] After every-second write command transmissions, a "0: writing in
progress" status is estab lished for 2 seconds. A "0: writing in prog-
ress" status is maintained for 2 seconds after completion of the final
write command transmission, and writ
ing then begins 2 seconds
la
ter, with a result of "1: successfully completed".
However, writing begins immediately following a initial reset executed in
response to a Data No. nn05 "initial reset request". A "1: successfully com-
pleted" result then occurs if all parameters have been saved to the nonvolatile
memory (EEPROM) approximately 3 seconds later.
- When "zero shift status save" is ON, writing begins immediately for Data No.
nn01 "zero shift execution request" and Data No. nn02 "zero shift reset execu-
tion request".
*10 The command reads the execution result of the "zero shift execution request" or
"zero shift reset execution request" whichever was last issued.