Keyence CV-X Series Manual do Utilizador Página 21

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 24
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 20
KEYENCE CORPORATION. Vision System Division
‐ 21 ‐ www.keyence.com
0 00 0 0 0
IN2
IN1
0 0
IN0
1 0 0 0 0
IN6
IN5
IN4
IN3
0 00 0 0 0 0 00 0 0 0 0
CST
CMD_CODE
CMD_PARAM
IN12
IN11
IN10
IN9
IN8
IN7
CST
CMD_CODE
CMD_PARAM
IN12
IN11
IN10
IN9
IN8
IN5
IN4
0 0 0 0
None
IN1
IN0
IN3
IN2
IN7
IN6
IN2
IN7
IN6
IN12
IN11
IN10
IN9
IN1
IN0
IN8
IN5
IN4
IN3
CST
CMD_CODE
CMD_PARAM
I/O terminal control (SS: Save Settings)
Saves the current Program Setting and Global Settings.
SS command: Save Settings
Save Settings
Sample SS command execution procedure
1. Set IN0 to 11 to OFF (open).
2. Set CST (IN12) to ON.
3. CMD_READY (OUT3) turns OFF, and the settings are saved.
4. When the settings are saved, ACK (OUT0) turns ON for the specified amount of time (set in "Global" >
"Communications & I/O" > "External Terminal"). When ACK turns off, CMD_READY (OUT3) turns ON.
* If the command execution fails, NACK (OUT1) turns on for the specified amount of time instead of ACK. Ensure that the
wiring and CMD_CODE/CMD_PARAM specifications are correct.
1: ON (short circuit), 0: OFF (open)
1: ON (short circuit), 0: OFF (open)
1: ON (short circuit), 0: OFF (open)
Vista de página 20
1 2 ... 16 17 18 19 20 21 22 23 24

Comentários a estes Manuais

Sem comentários