Keyence LK-3100 Manual do Utilizador Página 7

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 24
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 6
7
Controller
PART NAMES
Sensor head
0
MON(V)
MON(mA)
1
2
3
AUTO
GAIN
LOWHIGH
TIMING
STABULITY
BRIGHT
DARK
LASER ON
ZERO/RESET
SHIFT
RESET
SPAN
24V DC IN
REMOTE
GND
TIMING
ZERO
GND
ALARM
GND
NEAR
FAR
LASER
OFF
ON
+
1
2
3
4
5
6
7
LK
-
01 1
LASER ON
8
11
11
1 DIP switches
Set alarm hold function, key-lock function, and averaging function.
22
22
2 Sensor head connector
33
33
3 Sensitivity setting switch
Changes the received light sensitivity according to the reflectance of
the target. (
Refer to p. 14
)
44
44
4 Indicators
TIMING: Lights during synchronous (timing) input.
STABILITY: Lights yellow or green when a target is within the
measuring range. Lights red when a target is out of the measuring
range, or when the light quantity is insufficient or excessive.
BRIGHT: Lights when the light quantity is excessive.
DARK: Lights when the light quantity is insufficient.
LASER ON: Lights during laser emission.
55
55
5 SPAN adjustment keys
Finely adjusts the inclination of the analog output.
66
66
6 AUTO ZERO/RESET keys
Resets the analog output to 0 V (12 mA) at any point. Cancels
AUTO ZERO function.
77
77
7 SHIFT adjustment key
Finely adjusts the 0-point position of the analog output.
88
88
8 Operation indicator
Lights yellow or green when a target is within the measuring range.
Flashes yellow when a target is out of the measuring range, or when
the light quantity is insufficient or excessive.