3-3 Explicit Messaging
3-25
3
Communicating with the FD-S series
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-S) -
Command Parameter List for FD-S Series
The following tables provide command parameters for the FD-S series. The two types
of parameters are: motion command parameters and setting/status command
parameters.
Motion command parameters
For the communication methods using motion command parameters, see "Issuing
a Motion Command to a Sensor Amplifier" (page 3-19).
Attribute R: Read; C: Motion command
N: ID number of sensor amplifier
Setti
ng/status command parameters
For the communication methods using setting/status parameters, see "Reading/
Writing Settings or Status of a Sensor Amplifier" (page 3-20).
Attribute R: Read; W: Write; R/W: Read/Write
N: ID number of sensor amplifier. For example, if the ID nu mber is 13, then N x 10 + 3
-> 133 (DEC).
The data types are DINT unless explicitly specified.
InstID
(DEC)
AttrID
(HEX)
Name Description Attrib ute
N
64 Group-0 entr y count FD-SA*A:6, FD-SA*:5 R
65 Zero adjustment request Ex ecutes z ero adjustment. C
66
Integrated fl ow quantity reset
request
Resets integrated fl ow quantity . C
67
Instantaneous fl ow hold v alue
reset request
Resets instantaneous fl ow hold va lu e. C
68
Te mperature hold v alue reset
request
Resets temperature hold v alue . C
69
Initial reset req
uest (ALL)
Resets all settings of the sensor ampli fi er to
the f actor y def ault settings .
C
6A Initial reset (SLct)
Resets the sensor ampli fi er to the f actor y
def ault settings ., e xcept f or some items such
as z ero adjustment.
Av ailab le only to FD-S (v ersion A) .
C
InstID
(DEC)
AttrID
(HEX)
Name
Description
Attribute
Sens or
head
Default
value
Parameter range
Nx10+1
64
Group-1 entry count
R-21
65
Error state
*1 R - -
Bit 0: Always 0
Bit 1: Head connection error
Bit 2: Overcurrent Error
Bit 3: EEPROM Error
Bit 4: No fl ow error
Bit 5: Backflow error
Bits 6 - 8: Always 0
Bit 9: Drive gain error
Bit 10: Temperature lower error
Bit 11: Temperature high error
Bits 12 - 15: Always 0
66 to
67
System reserved
68
Output terminal state
*2 R - -
Bit 0: Output 1
Bit 1: Output 2
Bit 2: Output 3
Bits 3 - 15: Always 0