3-4 Message Communication
3-39
3
Communicating with the IL Series
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IL) -
Group1
0337H
(823)
Reset request
result
Indicates the result of reset.
Parameter range: 0 to 2
0:Executing
1:Normal termination
2:Abnormal termination
RDINT
0338H
(824)
Current system
parameters
*6
Indicates the current status of the system
parameters. Use this attribute to check the
system parameters with which the sensor
amplifier is actually operating.
The corresponding bit turns on according to
the current status.
bit 0:
0:NPN
1:PNP
bits 1, 2 and 3 (For main unit only. Fixed to
000 for expansion unit)
000: Analog output OFF
001: 0 to 5 V
010: -5 to +5 V
011: 1 to 5 V
100: 4 to 20 mA
RDINT
0339H
(825) to
033BH
(827)
(Reserved for system)
033CH
(828)
Tuning result
*7
Indicates the result of tuning.
Parameter range: 0 to 2
0:Executing
1:Normal termination
2:Abnormal termination
RDINT
033DH
(829)
Calibration result
Indicates the result of calibration.
Parameter range: 0 to 2
0:Executing
1:Normal termination
2:Abnormal termination
RDINT
033EH(8
30)
(Reserved for system)
033FH
(831)
(Reserved for system)
Group2
0340H
(832)
Group2 Entry
count
Indicates the No. of Group 2 entries.
Parameter range: 20
RDINT
0341H
(833)
HIGH setting
value
(BANK 0)
*2
Set up setting value of HIGH side (BANK 0).
Parameter range: -99.999 to +99.999
(initial value: +5.000)
R/W DINT
0342H
(834)
LOW setting
value
(BANK 0)
*2
Set up setting value of LOW side (BANK 0).
Parameter range: -99.999 to +99.999
(initial value: -5.000)
R/W DINT
0343H
(835)
Shift target
value
(BANK 0)
*2
Set up target value of shift (BANK 0).
Parameter range: -99.999 to +99.999
(initial value: 0)
R/W DINT
0344H
(836)
Analog output -
upper limit value
(BANK 0)
*2, *9
Set up upper limit of analog output (BANK 0).
(Main unit only)
Parameter range: (Main unit only)
-99.999 to +99.999
(initial value: +10.000)
R/W DINT
0345H
(837)
Analog output -
lower limit value
(BANK 0)
*2, *9
Set up lower limit of analog output (BANK 0).
(Main unit only)
Parameter range: -99.999 to +99.999
(initial value: 1.0000)
R/W DINT