- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IB) -
3-4 Message Communication
3-40
3
Communicating with IB Series
Group1
0332H
(818)
Laser
emission
stop status
Reads the transmission stop status of the
actually operating sensor amplifier. Check the
transmission stop status of the actually operating
amplifier from this attribute.
Parameter range: 0 to 1
0: Transmission now in progress
1: Transmission stop now in progress
(transmission stop input ON/laser errpr/head
error)
RDINT
0333H
(819)
Abnormal
setting
*3
Reads the abnormal setting status.
Parameter range: 0 to 1
0: Normal setting
1: Abnormal setting
RDINT
0334H
(820)
External
input status
Reads the external input setting status.
When the external input line of the sensor
amplifier or the external input of cyclic
communication is ON, the corresponding bit is
set to ON.
The external input operates even if "Not use" is
selected in External Input 1-4 Function Selection.
Bit 0: External input 1
Bit 1: External input 2
Bit 2: External input 3
Bit 3: External input 4
R
DWORD
0335H
(821)
EEPROM
writing
result
*4
Reads the EEPROM writing result.
Parameter range: 0 to 2
0: Writing now
1: Normal end
2: Abnormal end
RDINT
0336H
(822)
Zero shift
execution
result
*5
Reads the execution result of the zero shift or
zero shift reset.
Parameter range: 0 to 2
0: Zero shift or zero shift reset execution now in
progress
1: Normal end
2: Abnormal end (SHiFt Err)
RDINT
0337H
(823)
Reset
execution
result
Reads the reset execution result.
Parameter range: 0 to 2
0: Reset execution now in progress
1: Normal end
2: Abnormal end
RDINT
Class
Attribute
ID
Name Description
Attribute
Data
Ty p e