
20
Responsiveness
The time until 100% response of the internal judgment value can be
set from within the range of 3 to 5000 (ms).
The response time of the analog output (90% response) will be an
additional 2 ms from this point.
Power Save Mode
When
QP
is selected, if the key operation does not occur for 15
seconds (Power Save) will be displayed.
The “
”at the time of power save display will move from the left to
the right, and the operation indicator will operate normally. To return
the display status to normal, press any key. When there is an error,
regardless of whether power save mode is
QP
/
Q((
, the error will be
displayed.
Display Renewal Cycle
Set the interval to renew the display contents. When a value is increased,
only for that time the value will continue to be displayed the same. From
after the renewal until the next renewal, the measurement value will be
averaged so as to control fluctuations in the display value. However,
there will be no influence on the control output and the analog output.
Display inversion
When
PQ
is selected: regular display
When
;'5
is selected: The display will be inverted vertically 180°.
Time chart
Output
udgment
FT
/
FT
(OFF delay)
OFF
ON
F5
/
F5
(ON delay)
OFF
ON
Control output
after delay
Comentários a estes Manuais