GT2-100-M-E
High-accuracy Digital Contact Sensor
GT2-100
Series Instruction Manual
Symbols
The following symbols alert you to matters concerning the prevention of
human injury and product damage. Be sure to read these messages carefully.
Safety Information for GT2-100 Series
Other precautions
Effects of surrounding air temperature
To use the GT2-100 Series in high accuracy applications, do not use the GT2-100
Series in the environment in which the surrounding air temperature changes sharply.
It will take about 40 minutes on the 12 mm type, and 60 minutes for the 32 mm/50 mm type for the
internal temperature distribution to stabilize when the surrounding air temperature has changed by 10°C.
Warming up
The circuit is not stable immediately after the power turns ON, which
sometimes causes the indicated value to gradually fluctuate. Wait for about
5 minutes when using the 12 mm type and about 10 minutes when using
the 32/50 mm type after the power turns on before starting operation.
GT2-PA12K/PA12 (See illustration 1 for the pneumatic circuit)
This model uses a single-acting cylinder. The internal spring will
return the sensor head to its home position.
The air supply hole cannot be removed.
Use an air filter, mist separator, etc. to provide clean dry air. Empty the
drainage from the filter regularly, before it exceeds the specified line.
Before connecting the air tube to the air supply hole, be sure to blow plenty of
air through the pipes (flushing) to remove any foreign matter.
Make sure that the air pressure of the supplied air is constant and in the range
of 0.24 to 0.26 MPa. Use a precision regulator to control the air pressure. If
the air pressure is below 0.24 MPa, the spindle may not extend fully.
When supplying air (with the spindle extended), up to 3L/min of air will be
emitted from the tip of the dust seal.
The measuring ability of the device changes according to the air pressure
of the air supply. Refer to "Specifications" (Page 14) for details.
GT2-A12K(L)/A12(L)/A32/A50 (See illustration 1 for the pneumatic circuit)
This model uses a single-acting cylinder. The internal spring will return the sensor head to
its home position when air pressure is removed. DO NOT supply air to the exhaust valve.
The air cylinder cannot be removed.
Use the regulator to supply the stable air pressure to the sensor head.
Use the air filter and mist separators to supply dry air. Empty the
drainage from the filter regularly, before it exceeds the specified line.
Make sure that the air pressure of the air supply is constant and in the range of 0.25 MPa to 0.5 MPa.
The coupling socket and the exhaust valve that are supplied with the
air cylinder are dedicated for this product. They cannot be removed.
Power supply
Noise superimposed on the power supply may cause malfunction. Be sure to
use the DC stabilized power supply provided with an insulation transformer.
In the case of a commercially available switching regulator, be
sure to ground the frame ground terminal or the ground terminal.
About the dust boot
When the dust boot of the sensor head is damaged, use an optional dust boot sold
separately (For GT2-P12K(F)/P12(F)/H12K(F)/H12(F)/A12K/A12: OP-84332 (Material: NBR
(attached when shipped)). For GT2-P12K(F)/P12(F): OP-87859 (Material: Fluororubber).
For GT2-H32/A32: OP-84459 (Material: NBR (attached when shipped)). For GT2-H50/A50
(Material: NBR (attached when shipped)).). Attach the dust boot correctly.
The dust boot may deteriorate, depending on the environment it is
used in. In this case, replace the dust boot regularly.
*
Do not use the dust boot on the GT2-P12KL/P12L/PA12K/PA12/H12KL(F)/H12L(F)/H32L.
Precautions on Regulations and Standards
CE Marking
EMC Directive (2004/108/EC)
Applicable standardEMI:EN61326-1, Class A
EMS:EN61326-1
This product is designed for use in industrial environments.
The length of cable connected to the power supply terminal block
must be less than or equal to 30 m.
Remarks
These specifications do not give any guarantee that the end-product
with this product incorporated complies with the essential requirements of EMC
Directive. The manufacturer of the end-product is solely responsible for the
compliance on the end-product itself according to EMC Directive.
UL Certificate
UL File No. E120439 (Category: NRNT2/NRNT8)
Use the power supply with Class 2 output defined in NFPA70
(NEC: National Electrical Code).
GT2 series are evaluated as open type devices. These products
can not be a part of an enclosure.
WARNING
It indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
NOTICE
It indicates a situation which, if not avoided, could result
in product damage as well as property damage.
WARNING
If the following conditions are encountered, immediately turn
OFF the power. Continuing to use the GT2-100 Series under
these abnormal conditions may cause equipment failure.
When water or foreign matter enters the controller
When the GT2-100 Series is dropped or the housing is
damaged
When the GT2-100 Series produces smoke or an
abnormal smell
WARNING
Do not use the GT2-100 Series with a voltage other
than specified voltage, as this may cause fire, electric
shock or equipment failure.
Do not disassemble or modify the GT2-100 Series.
This may cause fire or electric shock.
Do not use this product for the purpose to protect a
human body or a part of human body.
This product is not intended for use as explosion-proof
product. Do not use this product in a hazardous
location and/or potentially explosive atmosphere.
NOTICE
Be sure to turn OFF the power of the GT2-100 Series and
any connected devices before connecting or disconnecting
the cables. Otherwise, there may be a risk of damage.
Do not turn OFF the power while setting parameters.
Otherwise, the settings may be partially or completely lost.
At startup and during operation, be sure to monitor the
function performance of the GT2-100 Series.
Do not modify the GT2-100 Series or use it in any way
other than described in the specifications.
The function performance of products used or modified
in this way cannot be guaranteed.
When the GT2-100 Series is used in combination with
other instruments, function performance may be degraded,
depending on operating conditions and the surrounding
environment. Use the GT2-100 Series after fully studying
the effect of combined use with other instruments.
Do not expose the GT2-100 Series and peripheral
devices to sudden temperature change. This may
cause condensation, damaging the equipment.
Environmental conditions
To use the GT2-100 Series properly and safely, do not
install the GT2-100 Series in the following locations.
Use of this equipment in an improper environment
may cause equipment failure.
Locations outside
Locations with high humidity, a large amount of dust,
or poor ventilation
Locations where the temperature rises excessively
due to direct sunlight, etc.
Locations near corrosive or flammable gas
Locations where the GT2-100 Series is directly
subjected to vibration or impact
Locations where water, oil or chemicals may come into
contact with the GT2-100 Series
Locations where static electricity may easily occur
Noise countermeasures
Installation near sources of electrical noise such as a
power source or a power cable may cause malfunction
or failure of the equipment. Adopt appropriate
countermeasures against noise by using a noise filter
or wiring cables in separate ducts, attaching insulation
to the amplifier or the sensor head, etc.
NOTICE
Handling of the sensor head
The GT2-100 Series and peripheral devices are precision
machines. Do not drop, or cause any other impact to these
devices. Doing so may cause damage or malfunction.
Do not apply force greater than what is listed below to the spindle. Do not
apply torque in the rotation direction. Otherwise the spindle may break.
The GT2-P12KL(F)/P12L(F)/PA12K/PA12 spindle can rotate a
maximum of about 4.5°. When using an offset contact (OP-
77683) or similar, if pressure in the rotational direction is
applied to the contact, the measurement position may change.
Although the GT2-PA12K/PA12/H12K/H12KF/H12/H12F/
H32/H50/A12K/A12/A32/A50 has a protection rating of
IP67, avoid using it immersed in water or in places where
liquid such as oil may come into contact with it.
Although the GT2-P12K(F)/P12(F) has a protection rating of
IP67G/NEMA Type 13, some types of oil may damage the device.
If dust, metal powder, or similar becomes attached to the sliding part
of the sensor head, mechanical responses may become slow. If this
happens, replace the dust seal with a replacement dust seal (OP-
87932). Refer to the instruction manual included with the replacement
dust seal (OP-87932) for instructions on how to replace the dust seal.
30 N 100 N
1 N
AIR
Mist separator
Pressure source
Air filter
Precision regulator
Solenoid
valve
Air supply part
Speed
controller
Illustration 1 - Pneumatic circuit
96M12754
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Series Instruction Manual

1GT2-100-M-EHigh-accuracy Digital Contact SensorGT2-100 Series Instruction Manual SymbolsThe following symbols alert you to matters concerning the pre

Página 2 - Package Contents

10GT2-100-M-EDefault values of basic settingsDefault values of added function settingsDefault values of calibration function settings Switching the di

Página 3 - Connecting the I/O connector

11GT2-100-M-E Basic setting modeYou can set the following functions in the basic setting mode.●How to enter the basic setting modeEnter the basic sett

Página 4 - Valid ID Setting

12GT2-100-M-E Additional function setting modeYou can set the following functions in the additional function setting mode.* Can be set only on ID00.●H

Página 5 - Mounting the sensor head

13GT2-100-M-E Calibration setting modeYou can set the following functions in the calibration setting mode.●How to enter the calibration setting modeEn

Página 6 - M4 screws

14GT2-100-M-ESpecifications Sensor headGT2-P***/PA*** cannot be connected to amplifier units purchased before April 15th 2014.●Pencil type (GT2-PA12K/

Página 7 - How to replace the dust seal

15GT2-100-M-E Amplifier●GT2-100N/E3N/100P/E3P*1 When the maximum number of sensor heads are connected, and all the sensor heads are set to the power-

Página 8 - Two-point tuning

16GT2-100-M-EInstalling the head cable connector (OP-84338)1Cut the cables to a necessary length.Peel back the cable insulation about 15 mm from the e

Página 9 - Reference

2GT2-100-M-EPackage ContentsThe product package of each model should include the following items. Check that all items are included before use. Amplif

Página 10 - Setting Mode Display

3GT2-100-M-E●Mounting on a tableWhen mounting the amplifier on a table, use the large amplifier mounting bracket (OP-84331).1Create on a table opening

Página 11 - Measurement direction change

4GT2-100-M-E3Attach the head expansion board with the screws.Attach the head expansion board with the two M3 screws used to mount the cover.To remove

Página 12 - Preset point setting

5GT2-100-M-EConnecting and Mounting the Sensor Head Names of parts of the sensor head* Not included in the GT2-P12KL/P12L.●GT2-H12K(L)(F)(LF)/H12(L)(F

Página 13 - Error message

6GT2-100-M-E1Cut the jig to create a sensor head mounting hole referring to the illustration below.2Insert the tightening sleeve into the hole (from t

Página 14 - Specifications

7GT2-100-M-E●Mounting with the mounting holesMount the GT2-H32(L)/H50/A32/A50 on the side of a table using the mounting holes on the side of the unit

Página 15 - I/O Circuit Diagram

8GT2-100-M-E How to mount the lift leverMount the lift lever (OP-84397) between the spindle and the contact. Secure the spindle with the lift lever an

Página 16 - WARRANTIES AND DISCLAIMERS

9GT2-100-M-E1When in the main display, press the left/right Arrow buttons until the HIGH setting value display appears.2Detect the good workpiece and

Comentários a estes Manuais

Sem comentários