Keyence IV Series Manual do Utilizador Página 100

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 110
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 99
A-6
- IV Series Users Manual (Field Network) -
Reference program (EtherNet/IP)
Program switching
Keyence KV series
Line 1
Line 2
Line 3
REQ
Program switching
response
Program switching
request
MOV
DM1000 Program No.
REQ
Program switching
request
Description of the reference program
z
Line 1
This line sets “REQ” to ON and copies the DM1000 data, which contains the program No. to be set, to the
program No.
z
Line 2/Line 3
Sets “REQ” to ON and executes a program switching request.
“Program switching response” ON to will set “Program switching request” to OFF (“Program switching
request” will be retained until “Program switching response” becomes ON).