1E SR-750 UMFixed Mount 2D Code ReaderSR-750 SeriesUser's Manual Rev.4.0 SymbolsThis user's manual uses the following symbols that alert yo
10E SR-750 UM3-2 Quick CalibrationThis section describes the Quick Calibration function.Quick CalibrationThe SR-750 Series automatically adjusts param
100E SR-750 UMLevel trigger operation procedureThis section describes the example when the trigger input measurement method of the SR-750 Series is se
101E SR-750 UMData processing procedure using the handshake processThis section describes the data processing procedure using the handshake process.Th
102E SR-750 UMResponsesThe following are the response formats sent from the SR-750 Series to the EtherNet/IP scanner. Response formatsMessage communi
103E SR-750 UMHow to decipher the SR-750 Series object tableReading the object table (attribute)Reading the object table (service)Data typeThe data ty
104E SR-750 UM1(0x01)107(0x6B)EXT. Request StatusUINTbit0 : Errorbit1 : Result Data Availablebit2 : Result Data Strobebit3 to 5 : Reservedbit6 : B
105E SR-750 UMSR-750 Series typical operation examples(1) Start reading (Read Start)Gives the command to start reading for the SR-750 Series.(2) Stop
106E SR-750 UM For the Control Logix/Compact Logix (RSLogix 5000)Description of tags used in the sampleReference program chartDescription of the refe
107E SR-750 UMReference program chartDescription of the reference programRung1 : When Read Complete and Read Failure are OFF, the read start message i
108E SR-750 UM[Message communication] Hardware reset processingThis is a reference program for hardware reset (restart) in message communication. For
109E SR-750 UM12-1PROFINETPROFINET is the open communication standard specified by PI (PROFIBUS & PROFINET International). PROFINET compatible dev
11E SR-750 UMActivation using AutoID Network NavigatorQuick calibration is performed using AutoID Network Navigator.Confirming the actual scanned imag
110E SR-750 UM21 byteBUSY Status Bits0BUSYOR of each BUSY signal0 : No BUSY status1 : BUSY status1 TRG BUSYMain unit in TRG BUSY status0 : No TRG BUSY
111E SR-750 UMPLC instruction area (Q address)The PLC instruction area is divided into areas as follows.Bit areaIn the following areas, information is
112E SR-750 UM13-1Installing MultiMonitorThis section describes how to install, start and shut down the MultiMonitor.Installation ProcedureThis sectio
113E SR-750 UM13-2Using MultiMonitorSoftware for real time monitoring of the SR-750 Series. This can display up to 16 SR-750 Series at once. This can
114E SR-750 UM14-1Installing FileViewThis section describes how to install, start and shut down the FileView.Installation ProcedureThis section assume
115E SR-750 UM14-2Using FileViewSoftware that isolates the FileView software function from AutoID Network Navigator. Without starting AutoID Network N
116E SR-750 UM15-1SR-750 Series SpecificationsGeneral Specifications*1 Barcodes fitted into the visual field range in size can be read.*2 The laser cl
117E SR-750 UM SR-750HAUnit: mm SR-752+SR-75L4 (400 mm lens)Unit: mm SR-752+SR-75L6 (600 mm lens)Unit: mmCode type Cell size A BDataMatrix, QR0.08
118E SR-750 UM Ethernet cable (OP-87356/87357/87358) NFPA79 compliant Ethernet cable (OP-87359/87360/87361)* For the dimensions after main unit chan
119E SR-750 UM15-4TroubleshootingIf you suspect that your SR-750 Series device is operating abnormally, check the following.If this does not solve the
12E SR-750 UM Bank prioritizing functionWhen the alternate setting order is set to "Begin with successful bank", the next reading starts fr
120E SR-750 UMHas the communication been blocked by security software of the PC?If security software is operating on the PC, it may be blocking the co
121E SR-750 UM15-5Checksum Calculation Method• A checksum can be appended to the read data when it is being sent.* No checksum can be appended to comm
122E SR-750 UM15-7Software LicenseSoftware License AgreementNOTICE TO USER: PLEASE READ THIS SOFTWARE LICENSE AGREEMENT (THIS "AGREEMENT") C
123E SR-750 UM15-9Copyright indicationsTOPPERS/JSP KernelToyohashi Open Platform for Embedded Real-Time Systems/Just Standard Profile KernelCopyright
124E SR-750 UMRevision HistoryDate of printingVersion Revision contentsMay 2013September 2013January 20142nd edition3rd edition4th editionErroneous de
13E SR-750 UM Starting reading rate test modeThe following procedures can be used to start and stop the reading rate test mode:• Start: Hold the bu
14E SR-750 UM3-5 Preset/Verification FunctionThis section describes the preset/verification function.Preset/Verification FunctionThis function allows
15E SR-750 UMInput terminal status and operationThe table below shows the relationship between the status of the input terminal and the operation of t
16E SR-750 UMTiming diagram (When OUT1 outputs an OK signal and then OUT2 outputs a NG signal)PointIf the same operation occurs again within the perio
17E SR-750 UMImage file nameAn image file name is set in the following format.(1) Image count value (3 bytes) IMG : When saved in ROM/RAM000 to 999 :
18E SR-750 UM(2) When the reading mode is the multi 2 read modeIn the multi 2 read mode, if reading judgments (Success or Failed) differ among paramet
19E SR-750 UMSilent mode setting procedureThe following 2 procedures for setting silent mode are available:• Setting using the AutoID Network Navigato
2E SR-750 UM11-1 EtherNet/IP... 9411-2 Cyclic communication...
20E SR-750 UM3-10Batch Setting CodeThis section describes the quick setup code.Quick Setup CodeUsers can print the settings specified with AutoID Netw
21E SR-750 UMCode quality verification function settingsThis section describes the setting method of the Code quality verification function and the se
22E SR-750 UMModulation MOD (Modulation)DescriptionEvaluates the variation degree in cell brightness―Calculation formulaEach cell's MOD = 2 ½ (ab
23E SR-750 UMISO/IEC TR 29158 (AIM DPM-1-2006)Decode success/failure DEC (Decode)Description Evaluates whether decoding is possible or not.―Calculatio
24E SR-750 UM3-12Duplicate reading prevention interval resetThe duplicate read prevention function is equipped with the Multi1 reading mode not to rea
25E SR-750 UM[2] Changing the script execution settingUsing the AutoID Network Navigator, set the script execution setting of the SR-750 Series to &qu
26E SR-750 UM4-1 Reading OperationsThis section describes the reading conditions of the SR-750 Series.Steps of Read OperationThe SR-750 Series follow
27E SR-750 UMPointWhen a code is read at an interval shorter than the specified output ON time, the OK/NG/ERROR output turns off even if the output ON
28E SR-750 UM4-4 Read ModeThe SR-750 Series offers 4 types of read modes. Select the appropriate type for your application. For most applications, use
29E SR-750 UMMulti 2 Read ModeMulti 2 read mode is used to read the codes in the parameter banks with registered settings in order while the trigger i
3E SR-750 UM1-1 Checking the Package ContentsThe packages of the SR-750 Series main units and the SR-750 Series configuration software contain the fol
30E SR-750 UM5-1 Installing, Starting, and Shutting DownThis section describes how to install AutoID Network Navigator as well as how to start and shu
31E SR-750 UM9 Click [Install].10Click [Finish].11Follow the same steps to "Install FileView" and "Install MultiMonitor". FileView
32E SR-750 UMAdding Reader with Register ButtonIf the SR-750 Series is on the different network, or it is placed on the network after starting AutoID
33E SR-750 UM5-2 Screen LayoutThis section describes the icons for AutoID Network Navigator.Screen(1) : Menu BarSome operations of the AutoID Network
34E SR-750 UM Configuration• Option window HelpThe Reader ListAutoID Network Navigator communicates with the connected SR-750 Series unit at specifi
35E SR-750 UMThe [Auto] screen(1) Configuration procedureButtons to switch between [Auto] and [Manual] modes.(2) PositioningLaser-Aim … Activate the l
36E SR-750 UMSymbology tab Code setting(5) : SymbologySpecify the code type for tuning.(6) : Code-specific settingSet the read length and detailed co
37E SR-750 UM Common•AlternateEnable: read the selected parameter bank, and use for reading operations.Disable: do not use the selected parameter ban
38E SR-750 UM[Code] tabIn the [Code] tab, set read digits for symbology registered in each parameter bank, as well as detailed items and output length
39E SR-750 UM Detailed setting for ITF Detailed setting for NW-7 (Codabar) Detailed setting for JAN/EAN/UPCEAN/JAN-13...Chec
4E SR-750 UMOperation status on the multiple LED indicator Run modeIn Run mode, the multiple LED displays a number, letter, or other symbol. Quick s
40E SR-750 UM[Communication2] tabSet communications in line with the control host that connects the SR-750 Series unit. These can be set or changedin
41E SR-750 UM[Operation] tabConfigures SR-750 Series operation. These can be set or changed in the [Table] tab.(1) Reading ModeSelect one of the follo
42E SR-750 UMEdit data(1) Additional InformationChecking the checkbox of data to add can set the Additional Information.Default : None for all items(2
43E SR-750 UM(2) • Image save modeDefault : Save final bank imageSetting range : Save final bank image, save specified number of images from timing ON
44E SR-750 UM• Connection requestSets whether the reader sends connection requests for PC host output. *Only when the interface is set to EthernetDefa
45E SR-750 UMOperation TIMING• Timing ModeSets the method of measuring timing.Default : Level triggerSetting range : Level trigger or One-shot trigge
46E SR-750 UM• SAE AS9132 verificationSets SAE AS9132 verification function.Default : DisableSetting range : Disable or Enable• SAE AS9132 verificatio
47E SR-750 UMI/O Input Terminal Common• Input polaritySets the input polarity of the IN terminal.Default : Norm. openSetting range : Norm. open or No
48E SR-750 UM• Keep connectedCheck this option to let reader send connection requests whenever the connection is closed.Default : DisabledSetting rang
49E SR-750 UM5-5Sending/Receiving ConfigurationThis section explains the transmission of a configuration between AutoID Network Navigator and the SR-7
5E SR-750 UMSetup FlowThis section describes the flow of the setup procedure required for starting the operation of the SR-750 Series.After unpacking
50E SR-750 UM2 Select a file from the "Open" dialog box.3 Click the "Open" button.The settings saved in that file will be displaye
51E SR-750 UM(1) Edit MessageArea in which to input commands to send to the SR-750 Series.• Header/TerminatorSpecify headers and terminators for comma
52E SR-750 UM(7) [Save image] buttonClick this to save the image displayed on the monitor screen.The default file name is <time indicated on PC>
53E SR-750 UMImage view screen in burst read modeThumbnail display is the burst read mode display.Display burst images in order of scanning, and displ
54E SR-750 UMCODE39CODE128GS1 DataBar Mounting conditionsInput the mounting distance of the SR-750 Series, and you can calculate the size of the fiel
55E SR-750 UM5-14Report Generator FunctionReport generator functionThe report generator function of the AutoID Network Navigator outputs tuning result
56E SR-750 UM5-15Creating Reports for the SR-750 SeriesData that can be generated as reportThe following data can be used for the SR-750 Series.• Inst
57E SR-750 UM Editing the report dataStart the report generator function and import the "Reading Report" to the Report Data section.The fol
58E SR-750 UMReference Image ReportThis can be used as a supplemental explanation report using other image data. Editing the report dataThe following
59E SR-750 UM Workpiece Report Reference Image Report
6E SR-750 UM2-1 Connecting the Power SourceThis section describes how to connect the SR-750 Series and the power source.Power supply to the SR-750 Ser
60E SR-750 UM6-1 Before Mounting the SR-750 SeriesThis section describes points to be checked before mounting the SR-750 Series.Check the mounting con
61E SR-750 UM2 Adjust the installation angle and distance of the SR-750 Series.Mounting the lens attachment (SR-75L4/75L6)Following is the mounting pr
62E SR-750 UM4 Press the "Monitor" button to check the code position.5 Press the "Tuning" button to perform calibration for the co
63E SR-750 UM7-1 Communication of the SR-750 SeriesTo communicate with a control device, the SR-750 Series has interfaces for RS-232C communication an
64E SR-750 UMAppending DataVarious types of data can be appended to read data. Read data formatThe data format for appending various types of data to
65E SR-750 UM Code vertex coordinates/Code center coordinatesAppends the coordinates of the vertexes and center position of the read code.• Data form
66E SR-750 UM*1 Enabled only for QR and micro QR code "-" is displayed for DataMatrix.*2 QR code Model 2 Version 7 and later versions are on
67E SR-750 UM7-3 RS-232C CommunicationThis section describes the RS-232C communication of the SR-750 Series.RS-232C Communication ConfigurationBefore
68E SR-750 UM7-4 Ethernet CommunicationUsing the Ethernet communication, you can send data from the SR-750 Series, or send operating instructions or c
69E SR-750 UM7-5 Socket CommunicationThis section described the behavior and configuration items of the SR-750 Series to perform socket communication.
7E SR-750 UM Control cable (NFPA79-compliant) with D-Sub9 pinz RS-232C wireThe tip of the RS-232C wire is a D-sub9-pin.z Control wire (Input/Output s
70E SR-750 UM Send NOOP commandWhen Send NOOP Command configuration is enabled, NOOP commands are sent periodically with the specified transmission i
71E SR-750 UM8-1 Details of Command CommunicationThis section describes the command types and communication format of the SR-750 Series. Types of Comm
72E SR-750 UM Timing OFF commandSend command LOFFResponse Normal process OK, LOFFAbnormal process ER, LOFF, ee ee: Error code• Starts and finishes re
73E SR-750 UMI/O Terminal Control Input terminal status checkSend command INCHK, mResponse Normal process OK, INCHK, n..m = 1 - 2: Terminal numbern =
74E SR-750 UM Forced trigger lock release Send command UNLOCKResponse Normal process OK, UNLOCKAbnormal process ER, UNLOCK, ee ee: Error code• Releas
75E SR-750 UM Obtaining the script versionSend command SCPVERResponse OK, SCPVER, mmmm, nnnnmm...:Script library versionnn…: FmtSet.lua version (Only
76E SR-750 UM Scan condition setting Code settingFunctionCommand NumberSetting valueExplanation DefaultLightingInternal lighting use0000, 10:Not use
77E SR-750 UM Reading operation settingJAN/EAN/UPC settings3500,1UPC-E reading0 : Disable1:Enable13510,1EAN/JAN 8 digits reading0 : Disable1:Enable13
78E SR-750 UMNW-7 (Codabar) settings0900 03 to 50 Maximum read length 500901 03 to 50 Minimum read length 40902 4 to 11 Quiet zone scale factor 70903
79E SR-750 UM Operation mode settingsOUT terminal settingOUT1 terminal assignment0200 to 31030 : Not selected1: OK2: NG4 : ERROR8: STABLE16 : PRESET
8E SR-750 UMWiring the RS-232C signal lineConnect to host devices (PC, PLC, etc.) as illustrated below: Connection to a PC Connection to the handhe
80E SR-750 UM Data appending function setting Verification/Preset function settingFunctionCommand NumberSetting valueExplanation DefaultTime appendi
81E SR-750 UM Tuning settingsCommunication Configuration Command Format (WN/RN)Communication configuration command is sent in the following format:•
82E SR-750 UM Data port 2 settingsFunctionCommand NumberSetting valueExplanation DefaultRemote IP address (TCP communication)300 a.b.c.da:0 to 255b:0
83E SR-750 UM SNTP settingsFunctionCommand NumberSetting valueExplanation DefaultRemote SNTP server address520 a. b. c. da:0 to 255b:0 to 255c:0 to 2
84E SR-750 UM Communication configuration commandChange commandConfirmation commandConfirmation command responsemmm : Command number Fixed to 3 bytes
85E SR-750 UM9-1 PLC LinkThis chapter presents an overview and the control method of the PLC link.PLC LinkThe PLC link allows the SR-750 Series to dir
86E SR-750 UMConfiguring the KV SeriesRS-232C Interface*1 To use port2, set the interface to "RS-232C".*2 For KV BUILDER/KV STUDIO mode, a f
87E SR-750 UMConfiguring the SYSMAC SeriesRS-232C InterfaceSet communication conditions with the CX-Programmer. CPU built-in portPLC system configura
88E SR-750 UMAssignment of Data Region FunctionsWhen the data region address D is specified, functions are assigned in order as shown below starting w
89E SR-750 UMData write processing method (A01 to A02, B02 to B04, D+03)The following 2 methods for writing data are available, depending on applicati
9E SR-750 UM3-1 Using the SR-750 SeriesThis section describes basic uses for performing reading operation using the SR-750 Series.Basic stepsBefore us
90E SR-750 UM9-4 Reference ProgramThis section introduces simple reference programs regarding the PLC link with the SR-750 Series.In actual operation,
91E SR-750 UM9-5 PLC Link ErrorThis section describes how to handle a communication error when it occurs during PLC link. Operation when a PLC link e
92E SR-750 UM10-1Master/Slave functionThe Master/Slave function has two types of modes: Multi drop link mode and Multi head mode. This section describ
93E SR-750 UM10-3Multi drop link modeWith the Multi drop link mode, reading operations of each SR-D100 or SR-750 Series are controlled by each unit. H
94E SR-750 UM11-1EtherNet/IPThis section describes an overview of EtherNet/IP.EtherNet/IPEtherNet/IP is an industrial communications network proposed
95E SR-750 UM11-2Cyclic communicationThis section describes the SR-750 Series cyclic communication setting procedures and functions.SR-750 Series cycl
96E SR-750 UM• Input OnlyThis connection can perform the following communications.• SR-750 → PLC... Data SendThis connection is used only w
97E SR-750 UMCyclic communication data assignmentData assignment during cyclic communication is performed as follows.Result data (Input Assemblies)Inp
98E SR-750 UMInput Assemblies (Address 1, Bit 8 to Bit 15) Error status* If any of the above errors occurs, the error code is output to "Failure
99E SR-750 UMParameter details of control data (Output Assemblies)Output Assemblies (Address 0, Bit 1 to Bit 7) Handshake/Clear bitOutput Assemblies (