1. Before Connecting EtherNet/IP (EtherNet/IP) [Keyence KV Series]
2
Change the Ethernet settings and then left-click
"OK".
1
From "Global", select "Communications & I/O" -
"Network".
3
From "Global", select "Communications & I/O" -
"EtherNet/IP".
4
Change the EtherNet/IP settings and then left-click
"OK".
1. Checking the Global Settings of the CV-X100 Series
In this section, the set values below will be configured
as an example (change the settings according to the
target device).
IP Address: 192.168.0.10
Subnet Mask: 255.255.255.0
In this section, the set values below will be
configured as an example (change the settings
according to the target device).
Enable EtherNet/IP: Check this box.
Data Size: 496 bytes
Data Configurations: Set the desired data
allocations and allocation offset for the bit
address and byte address.
Decimal Point: Fixedpoint
Process Priority: Image First
5
Restart the controller.
This section describes how to establish EtherNet/IP.
[Important]
If it fails, establish a one-to-one connection between the
PLC and CV-X, and follow this manual to configure the
settings and check the operations.
Confirm that it operates properly, and change settings if
necessary.