2. Changing the KV-Series settings
2
Enter the "Project name", select the "PLC model",
and then press "OK".
A "Confirm unit setting information" dialog appears.
3
Click "Read unit setting".
4
In the workspace, click the Ethernet/IP
communication unit or CPU unit that will be
connected to the CV-X100 Series to start "Unit
Editor". Set up the IP Address of the KV Series in
the "Setup unit (2)" tab.
IP Address: 192.168.0.20
Subnet Mask: 255.255.255.0
5
Select "Convert" - "Auto-assign relay/DM" in the
Unit Editor to allocate a device.
When automatically allocated, the bit device is
allocated to B (link relay) and the byte device is
allocated to W (link register).
6
Click the icon in "Setup unit (2)" to open
"EtherNet/IP settings". Configure the CV-X100
Series and EtherNet/IP communication settings.
Drag "CVX100" from the "Unit list (1)" tab in
"Eth
erNet/IP settings" and drop it into the scan list
to add it.
In the "Initial adapter settings" screen that is
displ
ayed after start up, enter the CV
100 S
eries
IP Ad
dress (192.168.0.10) that was set in the
CVX100
Series global settings.
7
Save the changes and exit the "EtherNet/IP
settings" and Unit Editor.
8
Select "Device comment edit window" from the
"Display" menu in KV STUDIO.
The "Device comment edit" screen appears.
9
Click "Details".
The "Register unit device" screen appears.
10
Confirm that the box for "CV-X100" is checked in
the "Select unit" list, and then click "Register".
Device comments regarding CVX100 are
automatically registered.
1
Start KV STUDIO with the PLC connected to the
computer, and select "New project" from the
"File" menu.