Keyence SL-V Series Manual do Utilizador Página 5

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 10
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 4
5
SL-V-IM-E
When using the muting bank function
The shielding wire of the PNP output type cable is connected to 0 V line in the SL-V.
Do not connect the shielding wire to +24 V line.
The shielding wire of the NPN output type cable is connected to +24 V line in the SL-V.
Do not connect the shielding wire to 0 V line.
When not using a non safety-related output, insulate the wires.
When using a simple function type cable (Automatic start/reset mode, When
not using the EDM function)
Meaning of symbols
K1, K2: External device (Safety relay unit, etc.)
PNP output type cable
NPN output type cable
When using a multi-function type cable (Other than automatic start/reset mode,
When using the EDM function)
Meaning of symbols
K1, K2: External device (Safety relay unit, magnet contactor, etc.)
K3 : Solid state contactor
*1
S1 : The switch for wait input (N.O.)
*1
The violet wire needs to be capped it is not used. (Open circuit : completely discon-
nected)
S2 : The switch for reset input (N.O.)
S3 : The switch for override input (N.O.)
L1 : Muting lamp (Incandescent lamp or LED lamp)
P1, P2 : Muting device (PZ self-contained photoelectric sensors, etc.)
M : 3-phase motor
PLC : For the monitoring use
*1
*1 These are NON SAFETY-RELATED system.
PNP output type cable
NPN output type cable
Example for Wiring
Brown
Blue
Muting bank input 1 (purple)
Muting bank input 2 (red/black)
Muting bank input 3 (pink)
Short-circuit current: 2.5mA
Transmitter
or
receiver
Main
circuit
0 V
+24 V
Brown
Blue
Muting bank input 1 (purple)
Muting bank input 2 (red/black)
Muting bank input 3 (pink)
Short-circuit current: 2.5mA
Transmitter
or
receiver
Main
circuit
0 V
+24 V
When using a PNP output type cable When using an NPN output type cable
Caution
Cable insulation: Black
Cable insulation: Grey
Transmitter
Receiver
(Interlock-reset-ready output) Green
(+24 V) Brown
(+24 V) Brown
(OSSD2) White
(OSSD1) Black
(Reset input) Yellow
(EDM input) Red
(Wait input) Violet
(AUX output) Red
(0 V) Blue
(0 V) Blue
Shield
Shield
K2
K1
(Interlock mode selection input) Pink
Orange/black
(Communication cable 2)
Orange
(Communication cable 1)
Cable insulation: Black
Cable insulation: Grey
Transmitter
Receiver
(Interlock-reset-ready output) Green
(+24 V) Brown
(+24 V) Brown
(OSSD2) White
(OSSD1) Black
(Reset input) Yellow
(EDM input) Red
(Wait input) Violet
(AUX output) Red
(0 V) Blue
(0 V) Blue
Shield
Shield
K2
K1
(Interlock mode selection input) Pink
Orange/black
(Communication cable 2)
Orange
(Communication cable 1)
S1
S2
S3
K1
K2
K2
K3
K2K1
M
IN
PLC
OUT
K1
L1
P 1
P 2
(Interlock mode selection input) Pink
Cable insulation: Black
Cable insulation: Grey
Transmitter
Receiver
(Interlock-reset-ready output) Green
(+24 V) Brown
(+24 V) Brown
(OSSD2) White
(OSSD1) Black
(Reset input) Yellow
(EDM input) Red
(Override input) Red/black
(Muting lamp output) Yellow/black
(Muting input 1) Light blue
(Muting input 2) Light blue/black
(Wait input) Violet
(AUX output) Red
(State information output 1) Grey
(State information output 2) Grey/black
(Alert output) Pink/black
(Clear/Blocked output) White/black
(0 V) Blue
(0 V) Blue
Shield
Shield
Orange/black
(Communication cable 2)
Orange
(Communication cable 1)
Brown
Brown
Blue
Blue
Black
Black
Use PNP output type for P1 and P2.
S1
S2
S3
K1
K2
K2 K1
L1
P 1
P 2
K3
K2K1
M
IN
PLC
OUT
Cable insulation: Black
Cable insulation: Grey
Transmitter
Receiver
(Interlock-reset-ready output) Green
(Interlock mode selection input) Pink
(+24 V) Brown
(+24 V) Brown
(OSSD2) White
(OSSD1) Black
(Reset input) Yellow
(EDM input) Red
(Override input) Red/black
(Muting lamp output) Yellow/black
(Muting input 1) Light blue
(Muting input 2) Light blue/black
(Wait input) Violet
(AUX output) Red
(State information output 1) Grey
(State information output 2) Grey/black
(Alert output) Pink/black
(Clear/Blocked output) White/black
(0 V) Blue
(0 V) Blue
Shield
Shield
Brown
Brown
Blue
Blue
Black
Black
Orange/black
(Communication cable 2)
Orange
(Communication cable 1)
Use NPN output type for P1 and P2.
Vista de página 4