9
SL-V-IM-E
Response time
Units: ms Units: ms Units: ms
*1 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) is to be 80ms or
more to ensure that the OSSD keeps OFF state for more than 80 ms.
When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response
times of all the individual SL-V units.
When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), and SL-V12L (12 beam
axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6 ms respectively, and the
response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
the response time (OFF to ON) is 27.1 ms + 40ms = 67.1 ms.
1.6 m/s is the maximum speed of movement of the test piece to which the detection capability is maintained.
Current consumption
Unit: mA
Unit: mA Unit: mA
*1 When the SL-V is used under surrounding air temperatures between 45 to 55°C, the Maximum load current should not
exceed 300 mA.
*2 Applies to situations when power is either off or disconnected.
*3 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable)
must be 2.5 ohms or less to ensure operation. If the cable length is 15 m or more and the load’s current consumption is
200 mA or more, the wire resistance must be 1 ohm or less.
*4 When operating in surrounding air temperatures ranging from 45 to 55°C, use incandescent lamps (24 VDC, 1 to 3 W)
or LED lamps (load current:10 to 100 mA)
You are fully responsible for performing the risk assessment on your machine application, taking into
account performing maintenance and inspections, which are critical factor for appropriate risk
assessment. In addition, it is a responsibility for the responsible personnel to train the machine oper-
ators regarding inspection and maintenance of the machine and the SL-V.
Inspection before operation (Initial inspection)
When the installation of the SL-V is completed, the responsible personnel must verify the operation of
the SL-V in accordance with the checklist shown below. Note that the following inspection items com-
prise only a bare minimum inspection. KEYENCE Corporation strongly recommends including the nec-
essary checking items into this checklist based on the judgment of the responsible personnel since
additional criteria may be necessary depending on both the machine to which the SL-V is installed and
the laws, rules, regulations and standards in the country or region in which the SL-V is used/installed.
(1) Pre-check for installation condition
The machine under SL-V control can be caused to stop running by the OFF-state of OSSD.
The SL-V is installed so that the machine operator cannot go into or approach the hazardous area
without passing through the detection zone.
The interlock reset mechanism is installed so that it cannot be operated if there are any personnel
within the hazardous area.
The device to activate the override is installed so that it cannot be operated if there are any per-
sonnel within the hazardous area.
The SL-V has been installed at a distance greater than or equal to the minimum safety distance required.
If there are glossy surfaces nearby, move them so that they are beyond the minimum installation
distance according to "Installation Distance From Glossy Surfaces".
The SL-V is installed at a location free from light interference, for example fluorescent lamps.
The transmitters and receivers are paired correctly.
The beam axis spacing (detection capability) is the same between the transmitter and the
receiver when installing the SL-V.
The muting devices fulfill the conditions specified in this instruction manual and the requirements of the laws,
rules, regulations and standards in the country or region in which the SL-V and those devices are used.
The devices used to activate the override fulfill the conditions specified in this manual and
requirements of the laws, rules, regulations and standards in the country or region in which the
SL-V and those devices are used.
Model
Response time
(OSSD)
Model
Response time
(OSSD)
Model
Response time
(OSSD)
ON to OFF OFF to ON
*1
ON to OFF OFF to ON
*1
ON to OFF OFF to ON
*1
SL-V23F/FM
9.1 49.1 SL-V08H 7 47
SL-V04L
6.5 46.5
SL-V31F/FM
10.2 50.2 SL-V12H/HM 7.6 47.6
SL-V06L/LM
6.8 46.8
SL-V39F/FM
11.3 51.3 SL-V16H/HM 8.1 48.1
SL-V08L/LM
747
SL-V47F/FM
12.4 52.4 SL-V20H/HM 8.7 48.7
SL-V10L/LM
7.3 47.3
SL-V55F/FM
13.5 53.5 SL-V24H/HM 9.2 49.2
SL-V12L/LM
7.6 47.6
SL-V63F/FM
14.6 54.6 SL-V28H/HM 9.8 49.8
SL-V14L/LM
7.8 47.8
SL-V71F/FM
15.7 55.7 SL-V32H/HM 10.3 50.3
SL-V16L/LM
8.1 48.1
SL-V79F/FM
16.8 56.8 SL-V36H/HM 10.9 50.9
SL-V18L/LM
8.4 48.4
SL-V87F/FM
17.9 57.9 SL-V40H/HM 11.4 51.4
SL-V20L/LM
8.7 48.7
SL-V95F/FM
19 59 SL-V44H/HM 12 52
SL-V22L/LM
8.9 48.9
SL-V103F/FM
20.1 60.1 SL-V48H/HM 12.5 52.5
SL-V24L/LM
9.2 49.2
SL-V111F/FM
21.2 61.2 SL-V52H/HM 13.1 53.1
SL-V26L/LM
9.5 49.5
SL-V119F/FM
22.3 62.3 SL-V56H/HM 13.6 53.6
SL-V28L/LM
9.8 49.8
SL-V127F/FM
23.4 63.4 SL-V60H/HM 14.2 54.2
SL-V30L/LM
10 50
SL-V64H/HM 14.7 54.7
SL-V32L/LM
10.3 50.3
SL-V72H/HM 15.8 55.8
SL-V36L/LM
10.9 50.9
SL-V80H/HM 16.9 56.9
SL-V40L/LM
11.4 51.4
SL-V88H/HM 18 58
SL-V44L/LM
12 52
SL-V96H/HM 19.1 59.1
SL-V48L/LM
12.5 52.5
SL-V104H 20.2 60.2
SL-V52L
13.1 53.1
SL-V112H 21.3 61.3
SL-V56L
13.6 53.6
SL-V120H 22.4 62.4
SL-V60L
14.2 54.2
Model
When the center
indicator is ON
When the center
indicator is OFF
Transmitter
Receiver
Transmitter
Receiver
SL-V23F/FM
83 78 80 74
SL-V31F/FM
93 80 90 75
SL-V39F/FM
103829977
SL-V47F/FM
112 85 107 78
SL-V55F/FM
121 87 115 80
SL-V63F/FM
129 89 122 82
SL-V71F/FM
136 92 129 83
SL-V79F/FM
142 94 135 85
SL-V87F/FM
148 97 140 87
SL-V95F/FM
154 99 145 88
SL-V103F/FM
159 101 149 90
SL-V111F/FM
163 104 152 92
SL-V119F/FM
166 106 156 93
SL-V127F/FM
169 109 158 95
Model
When the center
indicator is ON
When the center
indicator is OFF
Model
When the center
indicator is ON
When the center
indicator is OFF
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
SL-V08H
56 70 52 65
SL-V04L
48 70 45 66
SL-V12H/HM
63 72 58 66
SL-V06L/LM
53 71 50 67
SL-V16H/HM
69 74 64 67
SL-V08L/LM
59 72 55 67
SL-V20H/HM
75 75 70 68
SL-V10L/LM
64 74 59 67
SL-V24H/HM
81 77 76 69
SL-V12L/LM
69 75 64 68
SL-V28H/HM
87 79 81 69
SL-V14L/LM
74 76 68 68
SL-V32H/HM
93 80 86 70
SL-V16L/LM
79 77 72 69
SL-V36H/HM
98 82 91 71
SL-V18L/LM
84 78 76 69
SL-V40H/HM
103849672
SL-V20L/LM
88 80 80 70
SL-V44H/HM
108 85 100 73
SL-V22L/LM
93 81 84 70
SL-V48H/HM
113 87 104 74
SL-V24L/LM
97 82 88 71
SL-V52H/HM
117 88 109 74
SL-V26L/LM
101839271
SL-V56H/HM
122 90 112 75
SL-V28L/LM
105849571
SL-V60H/HM
126 91 116 76
SL-V30L/LM
109869872
SL-V64H/HM
130 93 120 77
SL-V32L/LM
113 87 102 72
SL-V72H/HM
137 96 126 78
SL-V36L/LM
120 89 108 73
SL-V80H/HM
144 98 132 80
SL-V40L/LM
126 91 113 74
SL-V88H/HM
149 101 136 81
SL-V44L/LM
132 93 119 75
SL-V96H/HM
154 104 140 83
SL-V48L/LM
137 95 123 75
SL-V104H
159 107 143 84
SL-V52L
142 97 127 76
SL-V112H
162 109 146 86
SL-V56L
146 99 131 77
SL-V120H
165 112 147 87
SL-V60L
150 101 134 78
Reference
NOTE
Common specifications
Model SL-VF/SL-VFM SL-VH/SL-VHM SL-VL/SL-VLM
Beam axis spacing/Lens diameter 10 mm/φ4 mm 20 mm/φ5 mm 40 mm/φ5 mm
Detection capability φ14 mm φ25 mm φ45 mm
Operating distance
0.1m to 7.0m
0.1m to 9.0m (detection height of 1,260mm or less)
0.1m to 7.0m (detection height of 1,400mm or more)
Effective aperture angle Max. ±2.5° (When operating distance is 3 m (9.84 ft.) or more)
Light source Infrared LED (850 nm)
Operation form
Turns on when no interruptions are present in the detection zone
Rating Power voltage 24 VDC +10%, -20% (Ripple P-P 10% or less), Class 2
OSSD
Output
2 outputs each for PNP and NPN.
Can be changed by using the connector cable
Max. load current
500 mA
*1
Residual voltage (during ON) Max. 2.5 V (with a cable length of 7 m (22.97 ft.))
OFF state voltage Max. 2.0 V (with a cable length of 7 m (22.97 ft.))
Leakage current
Max. 100 μA
*2
Max. capacitive load 1 μF (with a load resistance of 100 Ω)
Load wiring resistance
Max. 2.5 Ω
*3
Non safety-
related output
AUX
Output with automatic PNP/NPN switching function, 50 mA
max.
Interlock-reset-ready output
Alert output
Clear/Blocked Output
State information output 1, 2
Muting lamp output
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp
(load current :10 to 300 mA)
*4
can be connected
Input
EDM input Short-circuit current 10 mA
Wait input
Short-circuit current 2.5 mA
Reset input
Muting input 1, 2
Override input
Protection circuit
Reverse current protection, short-circuit protection for each
output, surge protection for each output
Environmental
condition
Enclosure protection
IP65 (IEC60529), IP65/67 (only for SL-VFM,SL-VHM and SL-VLM)
Overvoltage Category II
Operating ambient temperature -10 to +55°C (No freezing)
Storage ambient temperature -25 to +60°C (No freezing)
Operating relative humidity 15% to 85%RH (No condensation)
Storage relative humidity 15% to 95%RH
Surrounding light
Incandescent lamp: 5,000 lx or less. Sunlight: 20,000 lx or less
Vibration
10 to 55 Hz, 0.7 mm compound amplitude, 20 sweeps each in X, Y, and Z directions
Shock
100 m/s
2
(Approx. 10 G) 16 ms pulse, in X, Y, Z directions 1,000 times each axis
Material
Main unit case Aluminum
Upper case/Lower case Zinc die-cast
Front cover Polycarbonate, SUS304
Approved
standards
EMC
EMS IEC61496-1, EN61496-1, UL61496-1
EMI EN55011 ClassA, FCC Part15B ClassA, ICES-003 Class A
Safety
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL3)
EN ISO13849-1:2008 (Category 4, PL e)
UL508, UL1998
Checklist