Keyence LS-7000 Manual do Utilizador Página 100

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 99
4-48
Chapter 4 Function Settings
4
Strobe Output Time
Take the following steps to set the ON-time of strobe output.
1 Press the
ENT
key when the output
setting is displayed.
2 Press the
FUNC
key seven times.
HI
GO
LO
3 Press the or key and set the
output time.
4 Press the
ENT
key.
The input item is entered and the output
setting display appears again.
PROG No.
PRINT
AREA DISP
ESCPROG
FUNC
ENT
H
Z
E
FOCUS
2
1
AREA
POSITION
G
L
Output Logic
The logic of comparator output and WAITING output can be set to NO (normally open)
or NC (normally closed).
1 Press the
ENT
key when the output
setting is displayed.
2 Press the
FUNC
key eight times.
HI
GO
LO
3 Press the or key and set
the output logic.
The following displayed items can be
selected.
N.O.
(Normally open)
N.C.
(Normally closed)
GO
GO
PROG No.
PRINT
AREA DISP
ESCPROG
FUNC
ENT
H
Z
E
FOCUS
2
1
AREA
POSITION
G
L
4 Press the
ENT
key.
The input item is entered and the output setting display appears again.
Vista de página 99
1 2 ... 95 96 97 98 99 100 101 102 103 104 105 ... 191 192

Comentários a estes Manuais

flizz 28 Jan 2025 | 08:11:19

ok

Anil 07 Apr 2025 | 08:22:55

Hello