Keyence LS-7000 Manual do Utilizador Página 158

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 157
7-16
Chapter 7 RS-232C
7
Threshold Mode
LS
Output number
1 : OUT1
2 : OUT2
Command
Response
S D
,
A O
,
h m m m m m m m m
,
m m m m m m m m cr
,
S D
,
A O
,
h cr
+10V set value
Value setting format
(See page 7-13)
–10V set value
Value setting format
(See page 7-13)
Tolerance
This command changes tolerance settings. The LS-7000 Series will return an error
response if a command received is different in tolerance mode.
Reference Value Mode
UPPER
LS
Output number
1 : OUT1
2 : OUT2
Command
Response
Tolerance
Value setting format (See page 7-13)
S D
,
U P
,
h m m m m m m m m cr
,
S D
,
U P
,
h cr
STANDARD
LS
Output number
1 : OUT1
2 : OUT2
Command
Response
Tolerance
Value setting format (See page 7-13)
S D
,
S D
,
h m m m m m m m m cr
,
S D
,
S D
,
h cr
LOWER
LS
Output number
1 : OUT1
2 : OUT2
Command
Response
Tolerance
Value setting format (See page 7-13)
S D
,
L W
,
h m m m m m m m m cr
,
S D
,
L W
,
h cr