Keyence DL-PD1 Manual do Utilizador Página 52

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 51
3-6 DP-V1 Service
3-30
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT-70A) -
Executing Communication
3
97 Key lock DINT R/W 0
0: Unlock
1: Full key lock
98 Bank switching state *7 DINT
R 0 0 to 3:Currently active bank
W0
0: Switched to bank 0
1: Switched to bank 1
2: Switched to bank 2
3: Switched to bank 3
99 Timing status *8 DINT
R0
0: Timing input OFF, or in
process of measurement
using self-timing
1: Timing input ON, or not in
process of measurement
using self-timing
W0
0: Change during measurement
1
:
Change during non-measurement
100 to
102
Reserved for system
103 Bar display mode DINT R/W 0
0: Bar display mode
1: OK/NG display mode
104 to
127
Reserved for system
128 Group4 Entry count DINT R 26
129 Calculation mode and Setting *9 DINT R/W 0
0: OFF
1: Maximum value
2: Minimum value
3: Flatness
4: Average
5: Reference difference
6: Twist
7: Warpage
8: Thickness
130 Detection mode DINT R/W 0
0: Standard
1: NG hold
2: Peak hold
3: Bottom hold
4: Peak-to-Peak
131 Reserved for system
132 Response time DINT R/W 3
0: HSP (1.5 ms)
1: 5 ms
2: 10 ms
3: 100 ms
4: 500 ms
5: 1000 ms
6: 5000 ms
133 Timing type DINT R/W 0
0: External timing input
1: Rising self
2: Falling self
134 Self-timing level DINT R/W +000.5000 -099.999 to +999.999
135 Self-timing delay type DINT R/W 0
0: Static hold
1: Delay timer
136 User-specified delay time DINT R/W 1000 0 to 9999
137 Static hold determination DINT R/W 0
0: Default
1: User
138
Static hold stable range
DINT R/W +000.010 000.000 to +999.999
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value