I/O Terminal
7
Chapter
E LT-9001-IM
7-14
Timing Chart
Sampling cycle (T2), minimum input time (internal processing time, binary strobe cycle) (T1)
Timing Details (LT-9030 (M))
[ms]
Minimum input time
Scan width/ interval
Sampling cycle (T2) Internal processing time (T1)
OUT STB/BIN STB cycle
Displacement mode Displacement mode
OFF 0.64
120/2 43.6
120/4 23.1
120/8 19.2
240/2 84.6
240/4 42.3
240/8 28.2
400/2 143
400/4 67.9
400/8 41.0
560/2 188
560/4 93.6
560/8 53.8
4/1 2.6
* The sampling cycle(T2) differs according to the manufacturing variations of individual measuring units.
* The sampling cycle(T2) differs according to the settings of "Scan width/interval".
* The measurement response time, average measurement time, update cycle (T5), and RESET time (T4) vary according to the
change in the sampling cycle (T2).
* The minimum input time (internal processing time, binary strobe cycle) (T1) varies according to the setting of FINE mode.
Average measurement time, RESET time (T4), update cycle (T5)
Displacement mode
Number of measurement Average measurement
Number of data for RESET time
(T4)
Update cycle
(T5)
times for averaging time
moving average
2
T
2x2 1
T
2x3
T
2x
1
4
T
2x4 1
T
2x5
T
2x
1
8
T
2x8 1
T
2x9
T
2x
1
16
T
2x16 1
T
2x17
T
2x
1
32
T
2x32 1
T
2x33
T
2x
1
64
T
2x64 1
T
2x65
T
2x
1
128
T
2x128 2
T
2x129
T
2x
2
256
T
2x256 4
T
2x257
T
2x4
512
T
2x512 8
T
2x513
T
2x8
1024
T
2x1024 16
T
2x1025
T
2x16
2048
T
2x2048 32
T
2x2049
T
2x32
4096
T
2x4096 64
T
2x4097
T
2x64
* T2 is a sampling cycle.
* Number of times for averaging raging from 256 to 4096 can only be selected when the scanning width/interval is set to OFF in the
displacement mode. Refer to "SCAN" (page 3-15) for details.