4-2 Data Processing Time
4-4
4
Specifications
Sensor amplifier with calculation function ON
* For GT2-100 series, add 75 ms to the values above.
For details on the PLC scan time in (1) and the sensor amplifier response time in (4),
refer to the manual of each unit.
Number of connected sensor
amplifiers
Output, judgment value, or
current value
GT2 series*
1 11.3 ms
2 14.3 ms
3 20.3 ms
4 23.3 ms
5 29.3 ms
6 32.3 ms
7 38.3 ms
8 41.3 ms
8 47.3 ms
9 50.3 ms
10 56.3 ms
11 59.3 ms
12 65.3 ms
13 68.3 ms
14 74.3 ms