Parameters of Commands and Responses
z Read/write data
The following table lists the types of data that can be read from and written to IB Series sensor
amplifiers.
When data is written while the initial reset is being performed, the parameter error will occur
(Error number: 22). When writing data after the initial reset is performed, confirm that the
EEPROM writing result (Data number: 053) shows "1: Normal termination" and then write
data.
Data
No.
Data name
Data
format
*1
No. of
bytes
Attribute
*2
Data range Default value
001 Zero shift request * 1
R 0 - 1: Last written value
1
W0 o 1: Perform zero shift*
3
002 Zero shift reset request * 1
R 0 - 1: Last written value
1
W0 o 1: Perform zero shift reset*
3
003 Reset request * 1
R 0 - 1: Last written value
1
W0 o 1: Perform reset*
3
004 Error clear request * 1
R 0 - 1: Last written value
1
W0 o 1: Perform error clear *
3
*
4
005 Initial reset request * 1
R 0 - 1: Last written value
1
W0 o 1: Perform initial reset*
3
006 System parameter set request*
5
*1
R 0 - 1: Last written value
1
W0 o 1: Perform system parameter set*
3
010
Reference light registration
request
*1
R 0 - 1: Last written value
1
W
0 o 1: Perform reference light amount
registration
011 Adjust request * 1
R 0 - 1: Last written value
1
W0 o 1: Perform adjust*
3
012 Adjust reset request * 1
R 0 - 1: Last written value
1
W0 o 1: Perform adjust reset*
3
014 Tolerance tuning request * 1
R 0 - 1: Last written value
1
W0 o 1: Perform tolerance tuning*
3
015
2-point tuning HIGH side 1st
request
*1
R 0 - 1: Last written value
1
W
0 o 1: Perform 2-point tuning HIGH side 1st
point*
3
016
2-point tuning HIGH side 2nd
request
*1
R 0 - 1: Last written value
1
W
0 o 1: Perform 2-point tuning HIGH side
2nd point*
3
017
2-point tuning LOW side 1st
request
*1
R 0 - 1: Last written value
1
W
0 o 1: Perform 2-point tuning LOW side 1st
point*
3
018
2-point tuning LOW side 2nd
request
*1
R 0 - 1: Last written value
1
W
0 o 1: Perform 2-point tuning LOW side 2nd
point*
3
019
Measured correction 1st
request*
6
*
7
*1
R 0 - 1: Last written value
1
W
0 o 1: Perform measured correction 1st
point*
3
020
Measured correction 2nd
request*
6
*
7
*1
R 0 - 1: Last written value
1
W
0 o 1: Perform measured correction 2nd
point*
3
026 Logical correction 1st request*
6
*
7
*1
R 0 - 1: Last written value
1
W0 o 1: Perform logical correction 1st point*
3
027 Logical correction 2nd request*
6
*
7
*1
R 0 - 1: Last written value
1
W0 o 1: Perform logical correction 2nd point*
3
Point
Parameters of Commands and Responses
065 HIGH setting value (BANK 0) ±***.** *
8
7 R/W -999.99 to +999.99 20.00
066 LOW setting value (BANK 0) ±***.** *
8
7 R/W -999.99 to +999.99 10.00
067 Shift target value (BANK 0) ±***.** *
8
7 R/W -999.99 to +999.99 0.00
068 HIGH setting value (BANK 1) ±***.** *
8
7 R/W -999.99 to +999.99 20.00
069 LOW setting value (BANK 1) ±***.** *
8
7 R/W -999.99 to +999.99 10.00
070 Shift target value (BANK 1) ±***.** *
8
7 R/W -999.99 to +999.99 0.00
071 HIGH setting value (BANK 2) ±***.** *
8
7 R/W -999.99 to +999.99 20.00
072 LOW setting value (BANK 2) ±***.** *
8
7 R/W -999.99 to +999.99 10.00
073 Shift target value (BANK 2) ±***.** *
8
7 R/W -999.99 to +999.99 0.00
074 HIGH setting value (BANK 3) ±***.** *
8
7 R/W -999.99 to +999.99 20.00
075 LOW setting value (BANK 3) ±***.** *
8
7 R/W -999.99 to +999.99 10.00
076 Shift target value (BANK 3) ±***.** *
8
7 R/W -999.99 to +999.99 0.00
097 Key lock setting * 1 R/W
0: Disabled
1: Key lock
0
098 Bank setting*
9
*1R/W
0: Switch to bank 0
1: Switch to bank 1
2: Switch to bank 2
3: Switch to bank 3
0
099 Timing input*
10
*1R/W
0: Timing input OFF
1: Timing input ON
0
100 Laser emission stop input*
10
*1R/W
0: Laser emission stop input OFF
1: Laser emission stop input ON
0
104 Sub display's screen * 1 R/W
0: R.V. value screen
1: Analog output screen
2: HIGH setting value screen
3: LOW setting value screen
4: Shift target value setting screen
0
105 System parameter*
11
** 2 R/W
Main unit: 0 to 9
Expansion unit: 0 to 1
0
106 Tolerance tuning setting width ***.** *
12
6 R/W 0.00 to 999.99 10.00
107 Calibration function * 1 R/W
0: Do not correct (Initial state)
1: Measured correction
2: Logical correction
0
108
Measured/Logical correction
target 1*
6
*
7
±***.** *
8
7 R/W -999.99 to +999.99 0.00
109
Measured/Logical correction
target 2*
6
*
7
±***.** *
8
7 R/W -999.99 to +999.99 100.00
115 Logical correction measured 1*
6
*
7
±***.** *
8
7 R/W -999.99 to +999.99 0.00
116 Logical correction measured 2*
6
*
7
±***.** *
8
7 R/W -999.99 to +999.99 100.00
130 Measurement mode*
13
*1R/W
0: % mode
1: Dimension mode
0
131 Received/Blocked light mode * 1 R/W
0: Received light mode
1: Blocked light mode
0
Data
No.
Data name
Data
format
*1
No. of
bytes
Attribute
*2
Data range Default value
Vista de página 14