3-4 Command Parameter List
3-28
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -
Communicating with the FD-S series
3
00
nn31
Integrated flow
quantity (except
for version A)
R
FD-SS02 - -21474836.4 to +21474836.4
FD-SF1(S) -214748364 to +214748364
FD-SF1(F) -21474836.4 to +21474836.4
FD-SS2(S) -214748364 to +214748364
FD-SS2(F) -21474836.4 to +21474836.4
FD-SF8(S) -2147483.64 to +2147483.64
FD-SF8(F) -21474836.4 to +21474836.4
FD-SS20(S) -2147483.64 to +2147483.64
FD-SS20(F) -21474836.4 to +21474836.4
nn32 to
nn33
System reserved
nn34
External Input
Status
R- -
0: OFF
1: ON
nn35 System reserved
nn36
Shift system
processing result
R-0
0: Successfully completed.
1: Abnormally terminated
nn37 to
nn3F
System reserved
nn40
Group-2 entry
count
R-10
nn41
Instantaneous
flow rate setting 1
(P1)
*3 R/W
FD-SS02 030.0 000.0 to 400.0
FD-SF1(S) 0300 0000 to 2000
FD-SF1(F) 030.0 000.0 to 400.0
FD-SS2(S) 0300 0000 to 4000
FD-SS2(F) 030.0 000.0 to 400.0
FD-SF8(S) 02.00 00.00 to 16.00
FD-SF8(F) 0300 0000 to 4000
FD-SS20(S) 03.00 00.00 to 40.00
FD-SS20(F) 0300 0000 to 4000
nn42
Instantaneous
flow rate setting 2
(P2)
*3 R/W
FD-SS02 100.0 000.0 to 400.0
FD-SF1(S) 0500 0000 to 2000
FD-SF1(F) 100.0 000.0 to 400.0
FD-SS2(S) 1000 0000 to 4000
FD-SS2(F) 100.0 000.0 to 400.0
FD-SF8(S) 04.00 00.00 to 16.00
FD-SF8(F) 1000 0000 to 4000
FD-SS20(S) 10.00 00.00 to 40.00
FD-SS20(F) 1000 0000 to 4000
nn43
Temperature
upper limit setting
*6 R/W
SUS type 80.0
000.1 to 100.0
PFA type 60.0
nn44
Temperature lower
limit setting
*7 R/W - 10.0 000.0 to 099.9
nn45
Integrated flow
quantity setting 1
R/W - 0150 0000 to 9999
nn46
Integrated flow
quantity setting 2
R/W - 9999 0000 to 9999
Data
category
(HEX)
Data
number
(HEX)
Name
Description Attribute Sensor head
Default
value
Parameter range