3-3 Explicit Messaging
3-30
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -
3
Communicating with the SK-1000 Series
Nx10+1
73 to
76
Reserved
77
Abnormal setting
*8 R
0: Normal setting
1: Abnormal setting
78
External input status
*18 R
0 to 15
79
EEPROM writing result
*9 R 1
0: Writing
1: Normal termination
2: Abnormal termination
7A
Zero shift/Zero shift reset result
*10 R 1
0: Executing
1: Normal termination
2: Abnormal termination
7B
Reset execution result
*10 R 1
0: Executing
1: Normal termination
2: Abnormal termination
7C
System parameter current state
*11 R 0
Main unit: 0 - 9
Expansion unit: 0 - 1
7D to
83
Reserved
Nx10+2
64
Group-2 entry count
R17
65
HI setting value (BANK 0)
R/W 1.000
-99.999 to +99.999
66
LO setting value (BANK 0)
R/W -1.000
-99.999 to +99.999
67 to
69
Reserved
6A
HI setting value (BANK 1)
R/W 1.000
-99.999 to +99.999
6B
LO setting value (BANK 1)
R/W -1.000
-99.999 to +99.999
6C to
6E
Reserved
6F
HI setting value (BANK 2)
R/W 1.000
-99.999 to +99.999
70
LO setting value (BANK 2)
R/W -1.000
--99.999 to +99.999
71 to
73
Reserved
74
HI setting value (BANK 3)
R/W 1.000
-99.999 to +99.999
75
LO setting value (BANK 3)
R/W -1.000
-99.999 to +99.999
76 to
83
Reserved
Nx10+3
64
Group-3 entry count
R9
65
Key lock function
R/W 0
0: Release
1: Key lock
66
Bank function
*12 R/W 0
0: Switched to Bank 0
1: Switched to Bank 1
2: Switched to Bank 2
3: Switched to Bank 3
67
Timing input
*13 R/W 0
0: Timing input OFF
1: Timing input ON
68 to
6B
Reserved
6C
Sub display's screen
R/W 0
0: Temperature and humidity
1: Temperature
2: Humidity
3: HI setting value
4: LO setting value
5: RV value
6D
System parameter settings
*11 R/W 0
Main unit: 0 - 9
Expansion unit: 0 - 1
6E to
83
Reserved
InstID
(DEC)
AttrID
(HEX)
Name
Description
Attribute
Default
value
Parameter range