3-3 Explicit Messaging
3-31
3
Communicating with the SK-1000 Series
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -
Nx10+4
64
Group-4 entry count
R26
65
Reserved
66
Range setting
R/W 0
0: NEAR
1: FAR
2: Ib
67 to
68
Reserved
69
Averaging
R/W 5
0: 1 time
1: 2 times
2: 4 times
3: 8 times
4: 16 times
5: 64 times
6: 256 times
7: 1024 times
8: 4096 times
9: 16384 times
6A
Output mode
R/W 0
0: N.O.
1: N.C.
6B
Reserved
6C
Hold function setting
R/W 0
0: Sample hold
1: Peak hold
2: Bottom hold
3: Absolute value hold
4: Auto peak hold
5: Auto bottom hold
6: Auto absolute value hold
6D
Reserved
6E
Timing input setting
R/W 0
0: Level
1: Edge
6F to
70
Reserved
71
Hysteresis
R/W 0.100
0 to 99.999
72
Analog output scaling
*14 R/W 0
0: Initial state
1: Free range
73
Analog output upper limit
*14 R/W 10.000
-99.999 to 99.999
74
Analog output lower limit
*14 R/W
-10.000 -99.999 to 99.999
75
External input setting
*15 R/W 0
0: Initial state
1: User setting
76
External input 1
*15 R/W 0
0: Zero shift input
1: Bank A input
2: Bank B input
3: Not use
77
External input 2
*15 R/W 0
0: Reset input
1: Bank A input
2: Bank B input
3: Not use
78
External input 3
*15 R/W 0
0: Timing input
1: Bank A input
2: Bank B input
3: Not use
79
External input 4
*15 R/W 4
0: Bank A input
1: Bank B input
2: Not used
7A
Bank switching method
R/W 0
0: Button
1: External input
7B
Reserved
7C
Save zero-shift state
R/W 0
0: OFF
1: ON
7D
Reserved
InstID
(DEC)
AttrID
(HEX)
Name
Description
Attribute
Default
value
Parameter range
Comentários a estes Manuais