3-2 I/O Communication
3-5
3
Communicating with the FD-MH series
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-MH) -
Configure the operating mode setting switch to suite the operating mode to be used.
"Configuring the Operating Mode Setting Switch" (page 3-5)
*This is not available with the FD-MH series.
The memory size occupied by the DL-DN1 varies with the selected operating mode
and the number of connected sensor amplifiers.
3-output mode
Configuring the Operating Mode Setting Switch
DIP switch Operating mode
1 2 3 4 Output
Current
value
External
input
Bank
change
Setting value
rewrite
OFF OFF OFF OFF
3-output
No
No
No
No
OFF ON OFF OFF Ye s
OFF OFF OFF ON No
3-input
OFF ON OFF ON Ye s
OFF OFF ON OFF No
*
OFF ON ON OFF Ye s
OFF OFF ON ON No
No Ye s
OFF ON ON ON Ye s
ON OFF OFF OFF
5-output
No
No
No
No
ON ON OFF OFF Ye
s
ON OFF OFF ON No
5-input
ON ON
OFF ON Ye s
ON OFF ON OFF No
*
ON ON ON OFF Ye s
ON OFF ON ON No
No Ye s
ON ON ON ON Ye s
Occupied Memory
3-output
No extended mode Yes - -
3-input - Yes Ye s
Setting value rewrite - - Ye s
Area IN OUT IN OUT IN OUT
Number of sensor amplifi ers 1-10 8 0 14 6 22 24