3-3 Explicit Messaging
3-32
- DeviceNet Compatible Network Unit DL-DN1 User's Manual -
3
Communicating with the IB Series
Nx10+3
64
Group-3 entry count
R20
65
Key lock setting
R/W 0
0: Release
1: Key lock
66
BANK setting
*14 R/W 0
0: Switched to Bank 0
1: Switched to Bank 1
2: Switched to Bank 2
3: Switched to Bank 3
67
Timing input
*15 R/W 0
0: Timing input OFF
1: Timing input ON
68
Laser emission stop input
*15 R/W 0
0: Laser emission stop input OFF
1: Laser emission stop input ON
69 to
6B
Reserved
6C
Sub display's screen
R/W 0
0: R.V. value display screen
1: Analog output value screen
2: HIGH setting value screen
3: LOW setting value screen
4: Shift target setting screen
6D
System parameter
*12 R/W 0
Main unit: 0 - 9
Expansion unit: 0 - 1
6E
Tolerance tuning setting width
*16 R/W 10.00
0.00 to 999.99
6F
Calibration function
R/W 0
0: No correction (Default)
1: Measured correction
2: Logical correction
70
Measured/Logical correction target 1
*7 R/W 0.00
-999.99 to +999.99
71
Measured/Logical correction target 2
*7 R/W 100.00
-999.99 to +999.99
72 to
76
Reserved
77
Logical correction measured 1
*7 R/W 0.00
-999.99 to +999.99
78
Logical correction measured 2
*7 R/W 100.00
-999.99 to +999.99
79 to
83
Reserved
Nx10+4
64
Group-4 entry count
R30
65
Reserved
66
Measurement mode
R/W 0
0: Percent mode
1: Dimension mode
67
Received/Blocked light mode
R/W 0
0: Received light mode
1: Blocked light mode
68
Reserved
InstID
(DEC)
AttrID
(HEX)
Name
Description
Attribute
Default
value
Parameter range