Keyence DL-DN1 Manual do Utilizador Página 61

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 84
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 60
3-3 Explicit Messaging
3-33
- DeviceNet Compatible Network Unit DL-DN1 User's Manual -
3
Communicating with the IB Series
Nx10+4
69
Averaging/High-pass filter
R/W 5
Averageing
0: 1 time
1: 2 times
2: 4 times
3: 8 times
4: 16 times
5: 64 times
6: 256 times
7: 1024 times
8: 4096 times
9: 16384 times
High-pass filter
10: 0.1 Hz
11: 0.2 Hz
12: 0.5 Hz
13: 1 Hz
14: 2 Hz
15: 5 Hz
16: 10 Hz
17: 20 Hz
18: 50 Hz
19: 100 Hz
6A
Output mode
R/W 0
0: N.O. (normally open)
1: N.C. (normally closed)
6B
Reserved
6C
Hold function setting
R/W 0
0: Sample hold
1: Peak hold
2: Bottom hold
3: Peak-to-Peak hold
4: Auto peak hold
5: Auto bottom hold
6D
Auto hold trigger level
*7 R/W 90.00
-999.99 to +999.99
6E
Timing input setting
R/W 0
0: Level
1: Edge
6F
Delay timer
R/W 0
0: Delay timer OFF
1: On delay timer
2: Off delay timer
3: One shot timer
70
Timer duration
R/W 60
1 to 9999
71
Hysteresis
R/W 0.00
0.00 to 999.99
72
Analog output scaling
*17 R/W 0
0: No scaling (Default)
1: Free range
73
Analog output upper limit
*7
*17
R/W 100.00
-999.99 to +999.99
74
Analog output lower limit
*7
*17
R/W 0.00
-999.99 to +999.99
75
External input setting
*18 R/W 0
0: Default
1: User setting
76
External input 1 function selection
*18 R/W 0
0: Zero shift input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
77
External input 2 function selection
*18 R/W 0
0: Reset input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
InstID
(DEC)
AttrID
(HEX)
Name
Description
Attribute
Default
value
Parameter range