- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -
3-3 Cyclic communication
3-18
3
Communicating with the SK-1000 Series
The following describes how the scanner cyclically communicates with the DL-EP1
(cyclic communication).
"Reading an output from a sensor amplifier" (Page 3-18)
"Entering an external input to a sensor amplifier" (Page 3-19)
"Reading judgment values (P.V. values) from sensor amplifiers" (Page 3-20)
For the message communication method, refer to "Message communication"
(Page 3-4).
Reading an output from a sensor amplifier
Available outputs: HI, LO, GO, and alarm output
Device assignments: "Monitor Data (84 Words (168 Bytes)) Assembly Instance
(Instance ID): 64H" (Page 3-9)
This example shows how to read the HI output from the sensor amplifier ID01.
(1)The output from the sensor amplifier entered into the IN area via cyclic
communication.
Communication Methods
PLC
Output of sensor amplifier
IN area [18] Bit0
Sensor amplifier
(1)
Output
HI output of ID 01
1
0
ON
OFF