- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -
4-2 Data Processing Time
4-4
4
Specifications
Sensor amplifier with calculation function ON
For details on the PLC scan time in (1) and the sensor amplifier response time in (4),
refer to the manual of each unit.
Number of connected sensor
amplifiers
Output, judgment value, or
current value
1 11.3 ms
2 14.3 ms
3 20.3 ms
4 23.3 ms
5 29.3 ms
6 32.3 ms
7 38.3 ms
8 41.3 ms