Keyence DL-EP1 Manual do Utilizador Página 67

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 66
3-4 Message Communication
3-39
3
Communicating with the SK-1000 Series
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -
Group1
0338H
(824)
Current system
parameters
*7
Indicates the current status of the system
parameters. Use this attribute to check the
system parameters with which the sensor
amplifier is actually operating.
The corresponding bit turns on according to
the current status.
bit 0:
0:NPN
1:PNP
bits 1, 2 and 3 (For main unit only. Fixed to 000
for expansion unit)
000: Analog output OFF
001: 0 to 5 V
010: -5 to +5 V
011: 1 to 5 V
100: 4 to 20 mA
RDINT
0339H
(825) to
033FH
(831)
(Reserved for system)
Group2
0340H
(832)
Group2 Entry
count
Indicates the No. of Group 2 entries.
Parameter range: 17
RDINT
0341H
(833)
HI setting value
(BANK 0)
Set up setting value of HI side (BANK 0).
Parameter range: -99.999 to +99.999
(initial value: +1.000)
R/W DINT
0342H
(834)
LO setting value
(BANK 0)
Set up setting value of LO side (BANK 0).
Parameter range: -99.999 to +99.999
(initial value: -1.000)
R/W DINT
0343H
(835) to
0345H
(837)
(Reserved for system)
0346H
(838)
HI setting value
(BANK 1)
Set up setting value of HI side (BANK 1).
Parameter range: -99.999 to +99.999
(initial value: +1.000)
R/W DINT
0347H
(839)
LO setting value
(BANK 1)
Set up setting value of LO side (BANK 1).
Parameter range: -99.999 to +99.999
(initial value: -1.000)
R/W DINT
0348H
(840) to
034AH
(842)
(Reserved for system)
034BH
(843)
HI setting value
(BANK 2)
Set up setting value of HI side (BANK 2).
Parameter range: -99.999 to +99.999
(initial value: +1.000)
R/W DINT
034CH
(844)
LO setting value
(BANK 2)
Set up setting value of LO side (BANK 2).
Parameter range: -99.999 to +99.999
(initial value: -1.000)
R/W DINT
034DH
(845) to
034FH
(847)
(Reserved for system)
0350H
(848)
HI setting value
(BANK 3)
Set up setting value of HI side (BANK 3).
Parameter range: -99.999 to +99.999
(initial value: +1.000)
R/W DINT
0351H
(849)
LO setting value
(BANK 3)
Set up setting value of LO side (BANK 3).
Parameter range: -99.999 to +99.999
(initial value: -1.000)
R/W DINT
Class
Attribute
ID
Name Description
Attribute
Data
Typ e
Vista de página 66