Chapter 4 Use of Data Processing Functions
4
62
Sampling period
Specify the length of the sampling period after the hold-reset input.
The sampling delay time and sampling period are specified with time length.
The unit of the setting display is "ms".
Example
1000.1 = 1000.1 ms
Note 1: The reset delay and sampling delay can be specified within the range of
0.0 to 19999.9 ms.
Note 2: When "b-1" is selected as the measurement type, only "[-11" is displayed
to be set.
Note 3: When "b-2" is selected as the measurement type, only "[-0" is displayed
to be set.
Setting function "["
1. Press the key for at least 2 seconds.
The sensor enters the common function selection mode.
2. Press the
key to make function "[" flash.
3. Press the
or key to select the function setting mode.
4. Press the
key to select the desired function.
When "[-0" is selected
5. Press the key.
The sensor saves the setting and returns to the measurement state.
Trigger point
Starting point
The measured value is
displayed/output at this point.
(Time)
Sampling
delay time
Sampling period