Keyence FS-N10 Series Manual do Utilizador Página 43

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 42
3
Basic Operation
3-21
- Digital Fiber Sensor FS-N10 Series User's Manual -
3-7
Initialization
The sensor amplifier can be reset to the factory default settings.
1
Press and hold the [SET] and [PRE-
SET] buttons simultaneously for 3
seconds or more.
The "rSt" display flashes.
2
Press the [MODE] button.
3
Press the button to display
"init".
4
Press the [MODE] button.
After the settings are initialized, the
screen displays "oK", which is then
replaced with the current received light
intensity.
Refer to "Factory Default Setting (Default Value) List" on page 6-6.
Initialization of Settings (Reset to Initial Values)
Reference
Vista de página 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 115 116

Comentários a estes Manuais

Sem comentários