2.4 Instruction Details
1
2
3-139
Chapter 2 Instructions
Applications of TMIN (Analog timer) instruction
■ Changing the timer setting value
Uses the digital trimmer (TMIN0) to change the setting value of a timer (0 to 6553.5
sec.).
Coding
■ Changing setting values for multiple timers
Uses the digital trimmer (TMIN0) to change setting values for multiple timers (0 to
6553.5 sec.).
Coding
In the above example, T000, T001, and T002 have the same setting value.
Line No. Instruction Operand Line No. Instruction Operand
0000 LD 2002 0005 OR 0500
0001 TMIN 0 0006 TMR 000 #00010
0002 CON 0007 ANB T000
0003 STA T000 0008 OUT 0500
0004 LD 0000
0
TMIN
T000
STA
2002
0000
0500
0500
T000
#00010
T000
0
TMIN
T000
STA
T001
STA
T002
STA
#00010
T000
2002
0000
0500
T000
#00010
T001
0001
0501
T001
0500
0501
#00010
T002
0002
0502
T002
0502
Line No. Instruction Operand Line No. Instruction Operand
0000 LD 2002 0012 OUT 0500
0001 TMIN 0 0013 LD 0001
0002 CON 0014 OR 0501
0003 STA T000 0015 TMR 001 #00010
0004 CON 0016 ANB T001
0005 STA T001 0017 OUT 0501
0006 CON 0018 LD 0002
0007 STA T002 0019 OR 0502
0008 LD 0000 0020 TMR 002 #00010
0009 OR 0500 0021 ANB T002
0010 TMR 000 #00010 0022 OUT 0502
0011 ANB T000
TMIN / @TMIN
KVNKA Chap 02_4cP.p65 08.3.11, 0:02 PM139
Comentários a estes Manuais