3-4 Diagnostic Function
3-14
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -
Executing Communication
Example)
15
Slot 0 module status
0
00
B
:Normal
01
B
: System error
10
B
: The unit on the configuration
does not match the unit
actually connected.
11
B
: The unit is connected despite
the unit is not assigned on the
configuration, or the unit is not
connected despite the unit is
assigned on the configuration.
1
Slot 1 module status
2
3
Slot 2 module status
4
5
Slot 3 module status
6
7
16
Slot 4 module status
0
1
::
Slot 7 module status
6
7
17
Slot 8 module status
0
1
::
Slot 11 module status
6
7
18
Slot 12 module status
0
1
::
Slot 15 module status
6
7
19 Reserved for system
0
:
7
0000
B
(fixed)
Octet Content bit Value
DL-PD1
DL-PD1
IG-1000
IG-1050
IG-1050
IL-1050
10234
IG-1000
IG-1050
IL-1050
1023
Configuration on the
configuration software
Module status in the state as shown on
the left
Byte Value
10 00 00 10 01
B
11 10 00 00 10
B
12 00 00 00 00
B
13 00 00 00 00
B
14
10 00 00 00
B
3210 Slot number
15
00 00 00 11
B
7654 Slot number
::
Slot number
Slot number
Actual configuration