3-5 Overview of PROFIBUS DP Communication
3-21
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -
Executing Communication
3
Output
Functions assigned to the external input request 1 to 5 are as follows:
External input request 1: Zero shift input
External input request 2: TIMING input
External input request 3: RESET input
External input request 4: Standard waveform input
External input request 5: Laser emission stop input
Refer to the IG series user's manual.
Octet Bit Function name Description Value
0 to 4
0 External input request 1
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
1 External input request 2
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
2 External input request 3
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
3 External input request 4
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
4 External input request 5
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
5 Reserved for system - -
6 Reserved for system - -
7 Reserved for system - -
Vista de página 42