Advanced Functions
3
3-1 Data Processing and Operation Modes
OR mode
This mode is used when reading BCD output from multiple DL-RB1A units with one external device.
Set the external device so that there at least 2 ms before turning DRQ input on and after
turning DRQ input off.
Sample wiring
When sending BCD output from two DL-RB1A units to one external device.
- Perform OR wiring from the two BCD outputs to the external device input.
- Perform OR wiring from the two strobe outputs to the external device input or wire each input
independently.
- Wire both of the DRQ inputs independently from the two outputs on the external device (OR
wiring cannot be performed with the DRQ).
Note
Internal circuit
6 to 32
33 or 34
IN
COM
Photocoupler insulation
DL-RB1A Input to PLC etc.
Overcurrent protect circuit
Internal circuit
6 to 32
33 or 34
DL-RB1A
Overcurrent protect circuit
A
B