4-2 Basic Settings and Advanced Settings
4-13
IB-E
4
Setting Various Functions
According to the judgment value (P.V.), set the output mode (NO/NC) of judgment output
ON/OFF and edge check output.
There are three judgment outputs as below.
HIGH judgment output (Black wire)
GO judgment output (Gray wire)
LOW judgment output (White wire)
The judgment output is turned ON/OFF as below according to the tolerance setting value.
"3-6 Setting the Tolerance Setting Value" (page 3-13)
" 16. Check Output Function" (page 4-38)
When Normally Open is set
When Normally Closed is set
*1 " Error Displays and Corrective Actions" (page A-4)
*2 When the judgment value (P.V.) is [-----].
4. Output Mode
Item Setting range Default value
Output mode no (Normally Open), nC (Normally Closed) no
Judgment
Judgment output
HIGH GO LOW
HIGH ON OFF OFF
GO OFF ON OFF
LOW OFF OFF ON
Error
*1
ON OFF ON
-----
*2
OFF OFF OFF
Judgment
*1
Judgment output
HIGH GO LOW
HIGH OFF ON ON
GO ON OFF ON
LOW ONONOFF
Error
*1
OFF ON OFF
-----
*2
ON ON ON
Reference
Regardless of the output mode setting, the judgment indicator on the
amplifier unit interlocks the judgment output when Normally Open is set.
"3-6 Setting the Tolerance Setting Value" (page 3-13)
The following is the default state of the judgment indicator. The lighting
status can be changed in the items for “18. Display Color”.
" 20. Judgment Indicator Color" (page 4-41)
Judgment
Judgment output
HIGH GO LOW
HIGH
Lights in red OFF OFF
GO
OFF Lights in green OFF
LOW
OFF OFF Lights in red
Error Lights in red OFF Lights in red
----- OFF OFF OFF