4-2 Basic Settings and Advanced Settings
4-32
4
Setting Various Functions
IB-E
When Peak hold, Bottom hold or Peak-to-Peak hold is set
" 6. Timing Input" (page 4-23) setting: "Level"
" 6. Timing Input" (page 4-23) setting: "Edge"
Minimum input time
ON time: 0.5 ms
OFF time: 0.5 ms
When Auto peak hold or Auto bottom hold is set
Minimum input time
ON time: 0.5 ms
OFF time: 0.5 ms
Judgment value (P.V.)
judgment output
Max. 0.5 ms
Max. 0.5 ms
Min. 0.5 msMin. 0.5 ms
ON
OFF
Timing input
Max. 0.5 ms
Sampling period 1
Sampling period 1 result
Sampling period 2 result
Previous result
Sampling period
2
Judgment value (P.V.)
judgment output
Max. 0.5 ms
Max. 0.5 ms
Min. 0.5 msMin. 0.5 ms
ON
OFF
Timing input
Sampling period 1
Sampling period 1 result
Sampling period 2 result
Previous result
Sampling period 2 Sampling period 3
Max. 0.5 ms
Max. 0.5 ms
Max. 0.5 ms
Min. 0.5 msMin. 0.5 ms
ON
OFF
Timing input
Sampling is not started in this period
Sampling is started in this period