4-2 Basic Settings and Advanced Settings
4-26
4
Setting Various Functions
IB-E
The hysteresis for the tolerance setting value is set.
If the judgment value (P.V.) fluctuates due to the vibration of the object, etc. and the
judgment output repeats ON/OFF, increasing the hysteresis value stabilizes ON/OFF.
"3-6 Setting the Tolerance Setting Value" (page 3-13)
" 1. Measurement Mode" (page 4-8)
8. Hysteresis
Item Measurement mode Setting range Default value
Hysteresis
% mode 0.00 to 999.99
0.00
Dimension mode 0.000 to 99.999
0.000
The above is the timing chart when the output mode of judgment output is
Normally Open (default value). ON/OFF is reversed for Normally Closed.
" 4. Output Mode" (page 4-13)
Time
Hysteresis
Hysteresis
Judgment value (P.V.)
HIGH setting value
LOW setting value
ON
OFF
ON
OFF
ON
OFF
HIGH judgment output
GO judgment output
LOW judgment output