
6.3 Functions
Chapter 6 Handheld Programmer
1-225
1
6
• When the KV is write-disabled, the preset value cannot be changed.
• Any preset value of the timer/counter which is not set on the program cannot be
changed.
• TMH or TMS is specified using TMR.UDC is specified using CTR.
• The preset value in the source program is also changed.
*1. In the case where the counter (C) input is ON and the up-down counter (UDC)
reset input is OFF:
*2. In the case contrary to the above *1:
Key operation
Basic operation
Example of operation (In the PROGRAM mode)
When the TIMER/COUNTER SETTING CHANGE function is accessed, pressing
@
#, $
alternates between the decimal display and hexadecimal display.
CTC
ENT
R-SRCH
FNC
Timer (or counter) No.
ENT
R-SRCH
ENT
R-SRCH
Preset value
RES
0
LD
7
CTR
(C)
TMR
(T)
Key operation Display Description
RUN
Display arbitrary line.
LD 00000
T/C SET-V #00020 Access TIMER/COUNTER SETTING
TMR000 CHANGE [CHG: T/C SET-V] function.
T/C SET-V #00100 Specify CTR001. Then preset value of
CTR001 #00000 CTR001 is displayed.
T/C SET-V #00100 Enter desired value as new current
CTR001 #00200 value. (200)
T/C SET-V #00200
Preset value has been changed.
CTR001
00000
Return to initial display.
LD 00000
FNC
ENT
R-SRCH
CLEAR
SET
1
RES
0
ENT
R-SRCH
ENT
R-SRCH
RES
0
ANL
2
LD
7
CTR
(C)
AND
8
KVHKA Chap 06_3&4&5.p65 08.3.11, 11:17 AM225
Comentários a estes Manuais