7.6 Display Interface Mode Programming
KV-300 Series Only
KV-300
KV-10/80
Chapter 7 KV-L2 Serial Interface Module
1-290
7
Abort (XZ)
The abort command allows the KV-L2 to stop the current operation and accept a
new command. This command generates no response.
Abort command
Initialize
The command initializes all station nos. This command requires no station no., FCS,
and generates no response.
Initial command
Undefined command error response (IC)
This is a response returned when a command header code cannot be read or
undefined code was sent. Check the header code and send the correct code.
Response format
Error response when a command cannot be executed
This is an error response returned when a received command cannot be executed.
The error description is indicated in the end code.
Response format
Note 1: Header codes are specific to received commands.
Note 2: Some commands (combined commands) may have sub header code in
addition to the header code.
Station No.
nn
@
XZ FCS
C
R
Header
code
00 to 15
(in decimal)
Terminator
@
❋❋
C
R
Station No.
nn
@
IC FCS
C
R
Header
code
00 to 15
(in decimal)
Terminator
Station No.
nn
@
FCS
C
R
End code
nn
Header code
(sub-header code) of
received command
Terminator
KVHKA Chap 07_5to10.p65 08.3.11, 11:18 AM290