3-4 Command Parameter List
3-29
3
Communicating with the SK-1000 Series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
Setting/status command parameters
For the communication methods using setting/status parameters, see "Reading/
Writing Settings or Status of a Sensor Amplifier" (page 3-23).
To reduce the number of writes to the EEPROM, a write command is executed two
seconds after it is received. If another command is received within 2 seconds, the DL-
CL1 waits for another 2 seconds before executing the two commands in batch.
After the writing completes successfully, the "EEPROM w riting result" parameter
becomes "successfully completed (1)." For example, if commands are received
continually every second, they do not get executed because the DL-CL1 remains
"currently writing (0)." 2 seconds after the last command is received, the commands
received until then get executed in batch.
If data with a decimal point is used for a parameter range, ignore the decimal point
and read or write the data as an integer. For example, to wri
te a HI setting value
(BANK 0) of "+
1.235", write "+1235."
Attribute R: Read; W: Write; R/W: Read/Write
nn: ID number of sensor amplifier. Example: For nn41h and ID13, then 0D41h.
The data type is DINT (32-bit singed integer).
Data
category
(Hex)
Data
number
(Hex)
Name
Description Attribute
Default
value
Parameter description
00
nn20 Group-1 entry count R 24
nn21 Sensor amplifier error *1 R
0: Overcurrent error
1: EEPROM error
2: Sensor head error
3: 0 fixed
4: 0 fixed
5: 0 fixed
6: 0 fixed
7: Head temperature/humidity
error
8: 0 fixed
9: 0 fixed
10: 0 fixed
11: Amplifier communication
error
12: 0 fixed
13: 0 fixed
14: 0 fixed
15: 0 fixed
nn22 to
nn23
Reserved
nn24
Judgment output/Alarm
output
*2
*16
R
0: HI judgment output 0: OFF,
1: ON
1: LO judgment output 0: OFF,
1: ON
2: GO judgment output 0: OFF,
1: ON
3: Alarm output 0: OFF, 1: ON
nn25 Judgment value (P.V. value) *3 R -99.999 to +99.999
nn26
Internal measurement value
(R.V. value)
R -99.999 to +99.999
nn27
Peak-hold value during hold
period
*4
R -99.999 to +99.999
nn28
Bottom-hold value during
hold period
*5 R -99.999 to +99.999