3-4 Command Parameter List
3-31
3
Communicating with the SK-1000 Series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
00
nn68 Sub display's screen R/W 0
0: Temperature and humidity
1: Temperature
2: Humidity
3: HI setting value
4: LO setting value
5: RV value
nn69 System parameter settings *11 R/W 0
Main unit: 0 - 9
Expansion unit: 0 - 1
nn6A to
nn7F
Reserved
nn80 Group-4 entry count R 26
nn81 Reserved
nn82 Range setting R/W
0: NEAR
1: FAR
2: Ib
nn83 to
nn84
Reserved
nn85 Averaging R/W 5
0: 1 time
1: 2 times
2: 4 times
3: 8 times
4: 16 times
5: 64 times
6: 256 times
7: 1024 times
8: 4096 times
9: 16384 times
nn86 Output mode R/W 0
0: N.O. (normally open)
1: N.C. (normally closed)
nn87 Reserved
nn88 Hold function setting R/W 0
0: Sample hold
1: Peak hold
2: Bottom hold
3: Absolute value hold
4: Auto peak hold
5: Auto bottom hold
6: Auto absolute value hold
nn89 Reserved
nn8A Timing input setting R/W 0
0: Level
1: Edge
nn8B to
nn8C
Reserved
nn8D Hysteresis R/W 0.100 0.000 to 99.999
nn8E Analog output scaling *14 R/W 0
0: Initial state
1: Free range
nn8F Analog output upper limit *14 R/W
10.000
-99.999 to 99.999
nn90 Analog output lower limit *14 R/W
-10.000
-99.999 to 99.999
nn91 External input*15R/W0
0: Initial state
1: User setting
nn92 External input 1 *15 R/W 0
0: Zero shift input
1: Bank A input
2: Bank B input
3: Not use
nn93 External input 2 *15 R/W 0
0: Reset input
1: Bank A input
2: Bank B input
3: Not use
Data
category
(Hex)
Data
number
(Hex)
Name
Description Attribute
Default
value
Parameter description