Keyence DL-CL1 Manual do Utilizador Página 60

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 59
3-4 Command Parameter List
3-32
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
Communicating with the SK-1000 Series
3
*1 The error content of the sensor amplifier can be checked by noting the ON/OFF
state of each bit.
OFF (0): No error; ON (1): Error
More than one error may occur simultaneously. For details of each error, refer to
the SK-1000 Series Instruction Manual.
*2 Details of output status can be checked by noting the ON/OFF state of each bit.
00
nn94 External input 3 *15 R/W 0
0: Timing input
1: Bank A input
2: Bank B input
3: Not use
nn95 External input 4 *15 R/W 4
0: Bank A input
1: Bank B input
2: Not use
nn96 Bank switching method R/W 0
0: Button
1: External input
nn97 Reserved
nn98
Zero shift value memory
function
R/W 0
0: OFF
1: ON
nn99 Reserved
nn9A Display digit R/W 0
0: Initial state
1: 0.001
2: 0.01
3: 0.1
4: 1
nn9B to
nn9F
Reserved
nnA0 Group-5 entry count R 4
nnA1 Distance correction method R/W 0
0: Initial state
1: User setting
nnA2
Near-side distance correction
amount
R/W 25 5 to 50
nnA3
Far-side distance correction
amount
R/W 100 60 to 120
nnA4 Area scaling R/W 1.00 0.10 to 1.50
nnA5 to
nnBF
Reserved
nnC0 Group6 Entry count R 11
nnC1 Product code R
Main unit: 4024
Expansion unit: 4025
nnC2 Reserved
nnC3 Connected sensor head R 0
0: Not connected
1: The head is connected
nnC4 to
nnC7
Reserved
nnC8 Product name 1 *18 R
Main unit: "SK-1"
Expansion unit: "SK-1"
nnC9 Product name 2 *18 R
Main unit: "000/"
Expansion unit: "050/"
nnCA Product name 3 *18 R
Main unit: ""
Expansion unit: ""
nnCB Product name 4 *18 R
Main unit: ""
Expansion unit: ""
nnCC to
nnFF
Reserved
Data
category
(Hex)
Data
number
(Hex)
Name
Description Attribute
Default
value
Parameter description
Vista de página 59